Seaward Rigel PatSim200 Patient Simulator, its actual photo displayed.
- Brand NEW with warranty.
- Made in 2018
- Supplied in its original box with standard accessories.
- Can be Offered with a fresh calibration certificate at extra cost.
Features:
- 12 lead NSR ECG simulation
- Over 40 selectable Arrhythmias
- Performance waveforms
- Respiration simulation on lead I & II
- Universal temperature simulation
- Two channel IBP simulation
- Fetal simulation
- The new PatSim200 from Rigel was designed to make every patient simulation test you do quicker.
- Unlike other Patient Simulator models, the PatSim200 uses a home and recall function to easily move between tests and store your most used sequences, no more clicking and scrolling through ‘tree style’ hierarchy to perform each test.
- One of the most unique features of the PatSim200 is the ability to save 5 of your most used simulations and recall them at the touch of just 3 buttons.
- The unit itself is compact, lightweight and the full color screen with easily altered high contrast low luminance lighting means adapting the unit for use in low lighting environments is simple. On top of these great features we’ve also ensured that the PatSim200 comes with universal ECG studs and mini DIN connectors so the cost to change your Patient Simulators over to the PatSim200 won’t spiral out of control – our unit will work with most legacy IBP and temperature cables you already have.
Technical Specifications:
Simulation Type | |
---|---|
Full 12 lead ECG with independent outputs for each signal lead | |
Lead I | 70% |
Lead II | 100% |
Lead III | 30% |
Lead V1 | 24% |
Lead V2 | 48% |
Lead V3 | 100% |
Lead V4 | 120% |
Lead V5 | 112% |
Lead V6 | 80% |
ECG | |
---|---|
Normal Sinus Rhythm | |
Rates | 30, 40, 50, 60, 70, 80, 90, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300 BPM |
Rate Accuracy | ±1BPM or 1% |
Amplitude (lead II) | 0.05 to 0.45mV (0.05mV steps) 0.5 to 5.5mV (0.5mV steps) |
Amplitude Accuracy | ± 2% |
ST Segments | 18 selectable values, 8 elevated and 8 depressed -0.8 to +0.8mV in 0.1mV steps and +0.05mV and -0.05mV on Lead II |
Neonatal Mode | ECG R wave width is reduced to 40ms |
ECG Performance Tests | |
---|---|
Square Waves | 2Hz, 0.125Hz |
Triangle Wave | 2Hz |
Pulse | 60bpm or 240bpm |
Sine Waves | 0.05, 0.5, 1, 10, 25, 30, 40, 50, 60, and 100Hz |
Performance Amplitude | 0.5 to 5.0mV in 0.5mV steps |
Pacemaker | |
---|---|
Simulated Rhythms | Asynchronous at 75 BPM Demand with frequent sinus beat Demand with occasional sinus beat A-V sequential Non-capture Non-function |
Pulse Amplitude | 1.0, 2.0, 5.0, 10.0mV |
Accuracy | ±10% |
Width | 0.1, 0.2, 0.5, 1.0, 2.0ms |
Accuracy | ± 5% |
R-Wave Detector Test | 30, 60, 80, 120, 200, 250 BPM |
Haver-Triangle Width | 8, 10, 12, 20, 40 ,60, 80, 100, 120, 140, 160, 180, 200ms |
Performance Amplitude | 0.5 to 5.0mV in 0.5mV steps |
Arrhythmias | |
---|---|
Ventricular | Asystole Bigeminy Trigeminy Ventricular fibrillation (coarse) Ventricular fibrillation (fine) Ventricular tachycardia |
Supraventricular | Atrial fibrillation (coarse) Atrial fibrillation (fine) Atrial flutter Atrial tachycardia Missing beat Nodal rhythm Paroxysmal atrial tachycardia Sinus arrhythmia Supraventricular tachycardia |
Atrial Conduction | First degree AV block Left bundle branch block Right bundle branch block Second degree AV block – Mobitz I Second degree AV block – Mobitz II Third degree AV block |
Premature | Premature atrial contraction Premature nodal contraction Premature left ventricle contraction Premature left ventricle contraction – early Premature left ventricle contraction – R on T Premature right ventricle contraction Premature right ventricle contraction – early Premature right ventricle contraction – R on T Premature ventricular contraction – 6 / min Premature ventricular contraction – 12 / min Premature ventricular contraction – 24 / min Premature ventricular contraction – frequent multifocal |
Fetal Simulation | |
---|---|
Maternal Heart Rate | 80 BPM (Fixed) |
Fetal Heart Rate (Selectable) | 60, 90, 120, 140, 150, 210 and 240 BPM Fetal Heart Rate (IUP) 140 BPM at beginning, then varying with pressure |
Intrauterine-Pressure Waveforms | Early deceleration, late deceleration and uniform acceleration |
Simulation Period | Manual, or 2, 3, or 5 minutes |
Invasive Blood Pressure | |
---|---|
Channels | 2 channels |
Static Pressure | -10, -5, 0, 20, 40, 50, 60, 80,100, 150,160, 200, 240, 320, 400mmHg |
Dynamic Simulation | Arterial [ART] 120/80 Radial Artery [RA] 120/80 Left Ventricle [LV] 120/00 Right Ventricle [RV] 25/00 Right Atrium (central venous) [CVP] 15/10 Pulmonary Artery [PA] 25/10 Pulmonary Artery Wedge [PAW] 10/2 Left Atrium [LA] 14/4 |
Auto Sequence (Channel 1 only) | |
Cycle through simulations with 15 second step duration: | Arterial [ART] 120/80 Radial Artery [RA] 120/80 Left Ventricle [LV] 120/00 Right Ventricle [RV] 25/00 Pulmonary Artery Wedge [PAW] 10/2 Pulmonary Artery [PA] 25/10 Right Atrium (central venous) [CVP] 15/10 |
Accuracy | ± 1mmHg |
Excitation voltage | 2 to 16V |
Impedance | 350Ω Nominal |
Simulated sensitivity | 5μV/V/mmHg or 40μV/V/mmHg (user selectable) |
Connector | mini DIN style |
Temperature | |
---|---|
Simulation | YSI 400 / 700A / 700B Static |
Temperature Unit | °C or °F, user selectable |
Range | 0.0, 24.0, 37.0, and 40.0°C 32.0, 75.2, 98.6, 104.0°F |
Accuracy | ± 0.1°C / °F |
Connector | Mini DIN style |
Respiration | |
---|---|
Rates | Selectable values of 0, 5, 10, 15, 30, 40, 60, 80, 120, 180 brpm |
Lead Selection | Lead I and II, user selectable |
Base Resistances | 500, 1000, 1500 & 2000Ω |
Accuracy | ±5% |
Resistance Variations | 0.2, 0.5, 1.0, 3.0Ω |
Accuracy | ±10% |
Apnoea Simulation | Manual ON / OFF |
General Specifications
Mains Power/Battery Info | 3.7V 3900mAh 14.4WH Li-Ion battery 5V 1A USB micro-B power supply 100-240V ~ 50/60Hz 0.18A max. |
Charge Time (new battery) | Up to 3-4 hours |
Battery Life | Up to 6 hours, ~4 hours |
Weight | 0.70kg / 1.5lbs |
Dimensions | 180 x 150 x 55mm, 7.1 x 5.9 x 2.2″ |
Environmental Specifications | |
---|---|
Operating Conditions | 10 – 40°C (50 – 104°F) 0-90% RH – NC |
Storage Environment | -15 – 60°C (5 – 140°F) 0-90% RH – NC |
Environmental Protection | IP40 |
Part Number | |
---|---|
PatSim200 | 404A920 |