AngioDynamics Diomed DELTA 15 Diode Laser unit in very good physical and operational condition, unit’s actual photo displayed.
- Serial No. 003596
- Made In: UK
- Date of manufacture 12/2006
- Voltage 100-240V, 500VA, 50/60Hz
- Version: 41.16
*** Supplied with:
- Diomed delta Foot switch
- User manual
- 1 x key
- 1 x remote interlock bypass
*** Key features of the DIOMED DELTA 15 include:
- • 15W power output
- • Compact & portable
- • Intuitive user interface
- • Automatic procedure recognition when used with fibers and accessories conforming to the
DIOMED FRS fiber system - • Minimal maintenance & service
- • DELTA 15 has been designed for use with the DIOMED range of procedure kits, such
as those for EVLT (EndoVenous Laser Treatment). It can also be used with a wide range of standard fibers and accessories.
*** Indications: The DIOMED DELTA 15/30 is intended for the following contact or non-contact
laser procedures:
- • Incision (only contact)
- • Excision (only contact)
- • Vaporisation
- • Coagulation / haemostasis
– of soft tissue in Endovascular, open and endoscopic procedures in Vascular
Surgery, General Surgery, Gynaecology, Urology, Otorhinolaryngology
(ENT)/Head & Neck Surgery, Ophthalmology (oculoplastics),
Pulmonology/Thoracic surgery, Plastic Surgery, Gastroenterology and
Neurosurgery.
*** SPECIFICATIONS:
- Laser Type: Diode laser, CW
- Centre wavelength: 810 nm
- Spectral bandwidth: 90% of optical power contained within 810 ± 20 nm
- Delivery fiber: Minimum 400 µm diameter, 0.37 Numerical Aperture (NA)
- Fiber connector: Optical SMA-905 to MIL STD
- Maximum Power: 15 W to the laser output port
- Minimum Power: 0.5 W to the laser output port
- Set power accuracy Better than ± 10% of displayed power
- Output power stability: ± 5% maximum
- Aiming beam: Red Class 3a diode laser, ≤ 5 mW at port, wavelength 635-655 nm
- Pulse duration: 100 ms – 9900 ms, Continuous Wave (CW)
- Pulse Interval: 100 ms – 1000 ms
- Countdown timer: 10 – 3200 seconds
- Fibers: Contact fibers, 400µm, 600µm and 1000µm, Non-contact fibers, 600µm & 1000µm
- Calibration: Internal power calibration meter for handpiece or fiber calibration (Optional on DIOMED DELTA 15)
- Spot Handpiece Mode: Spot handpiece mode is available on the DIOMED DELTA 15 when fitted with the optional calibration meter
- Spot size: Ø 2mm
- Single/Repeat Pulse: 50ms – 250ms
- Pulse Interval: 100ms – 1000ms
- Fluence Up to: 119J/cm2
- Fiber Recognition System: (FRS)
- Operating Frequency: 125 kHz ± 1 kHz
- Operating Range: Maximum of 40 mm from the laser output port
- RFID Modulation Type: A1D
- Standards: FCC 47 Part 15c, Canadian RSS-210 EN 300 330-1, EN 300 330-2, EN 301 489-1, EN 301 489-3
Cooling By ambient air, with fan assistance - Power Supply: 100 – 240 V AC, 50 – 60 Hz, 500 VA max.
- Dimensions (H x W x D): 150 mm x 370 mm x 325 mm (± 5 mm)
- Weight: 12 kg max.
- Operating Temperature: +10ºC to +40ºC
- Operating Humidity: Up to 75% relative humidity, non-condensing
- Operating Pressure: Normal atmospheric pressure
- Storage Temperature: 0ºC to +55ºC
- Storage Humidity: Up to 90% relative humidity, including condensing
- Safety Standards: EN 60601-1, EN 60601-1-2, EN 60601-2-22, EN 60825-1, 21 CFR 1040.10, 1040.11