IVY Biomedical 7800 Cardiac Trigger Monitor with Stand


£1,250.00

The IVY Biomedical 7800 Cardiac Trigger Monitor is a specialised, high-precision cardiac monitoring device designed to provide reliable R-wave detection and accurate cardiac triggering for synchronised medical procedures. Commonly used in MRI, CT, and nuclear medicine environments, the 7800 ensures stable cardiac gating signals to support high-quality imaging and treatment workflows.

Engineered for dependable performance, the unit features advanced ECG signal filtering, adjustable trigger thresholds, and real-time waveform display, allowing clinicians to achieve optimal synchronisation even in challenging monitoring conditions. Its compact, lightweight design makes it easy to integrate into any clinical setup.


Technical Specifications:

Specification Details
ECG Configuration 4-lead system
Trigger Lead Options Lead I, II, III, or AUTO (menu selectable)
Second Lead Display Lead I, II, or III
Patient Cable 4-lead cable with 6-pin AAMI connector
Patient Isolation > 4 kV rms, 5.5 kV peak
Frequency Response (ECG) 0.67 – 100 Hz (unfiltered)
Filtered Response 1.5 – 40 Hz; auto 50/60 Hz notch filter
CMRR ≥ 90 dB
Tall T-Wave Rejection ≤ 1.2 × R-wave amplitude
Pacer Pulse Rejection 0.1 – 2 ms width @ ±2 to ±700 mV (user selectable)
Defibrillator Protection 360 J discharge, < 5 sec recovery (Type CF)
Heart Rate Range Adult: 10–300 bpm; Pediatric/Neonate: 10–350 bpm
Heart Rate Accuracy ±1% ± 1 bpm
HR Resolution 1 bpm
Sensitivity 300 µV (peak)
HR Averaging Exponential @ 1 Hz; 2 or 8 s response time
Alarms High Rate: 15–250 bpm (5-bpm steps)
Low Rate: 10–245 bpm (5-bpm steps)
Asystole: R-R > 6 sec
Lead Off / Check Lead
ECG Simulator Built-in; 1 mV amplitude, 10–250 bpm
Display 8.4″ TFT colour touch-screen LCD, 640×480 resolution
Synchronized Output < 2 ms delay; R-R accuracy ±75 µs typical; Output impedance < 100 Ω
Trigger Output Settings Pulse width: 1 / 50 / 100 / 150 ms
Amplitude: 0–+5 V or –10 to +10 V
Polarity: Positive or Negative
Interfaces / I/O BNC Sync Output
¼″ ECG Analog Output
DB-9 X-ray/Aux
RS-232
Ethernet (10Base-T)
USB Memory Stick
Optional Recorder 2-trace direct-thermal strip chart recorder
Dimensions (H × W × D) 22.14 × 23.50 × 15.49 cm (8.72″ × 9.25″ × 6.10″)
Weight 2.54 kg (5.6 lb)
Power Requirements 100–120 V or 200–230 V AC, 50/60 Hz; 45 VA max
Operating Conditions 5°C–40°C; 0–90% RH (non-condensing); altitude –100 to +3,600 m; IPX1
Storage Conditions –40°C to +70°C; 5–95% RH; altitude –100 to +14,000 m
Regulatory Standards IEC 60601-1, IEC 60601-2-27, AAMI EC-13, CE, ISO 13485

1X Used unit in stock. £990 for unit alone without stand.