The IVY Biomedical 7800 Cardiac Trigger Monitor is a specialised, high-precision cardiac monitoring device designed to provide reliable R-wave detection and accurate cardiac triggering for synchronised medical procedures. Commonly used in MRI, CT, and nuclear medicine environments, the 7800 ensures stable cardiac gating signals to support high-quality imaging and treatment workflows.
Engineered for dependable performance, the unit features advanced ECG signal filtering, adjustable trigger thresholds, and real-time waveform display, allowing clinicians to achieve optimal synchronisation even in challenging monitoring conditions. Its compact, lightweight design makes it easy to integrate into any clinical setup.
Technical Specifications:
| Specification | Details |
|---|---|
| ECG Configuration | 4-lead system |
| Trigger Lead Options | Lead I, II, III, or AUTO (menu selectable) |
| Second Lead Display | Lead I, II, or III |
| Patient Cable | 4-lead cable with 6-pin AAMI connector |
| Patient Isolation | > 4 kV rms, 5.5 kV peak |
| Frequency Response (ECG) | 0.67 – 100 Hz (unfiltered) |
| Filtered Response | 1.5 – 40 Hz; auto 50/60 Hz notch filter |
| CMRR | ≥ 90 dB |
| Tall T-Wave Rejection | ≤ 1.2 × R-wave amplitude |
| Pacer Pulse Rejection | 0.1 – 2 ms width @ ±2 to ±700 mV (user selectable) |
| Defibrillator Protection | 360 J discharge, < 5 sec recovery (Type CF) |
| Heart Rate Range | Adult: 10–300 bpm; Pediatric/Neonate: 10–350 bpm |
| Heart Rate Accuracy | ±1% ± 1 bpm |
| HR Resolution | 1 bpm |
| Sensitivity | 300 µV (peak) |
| HR Averaging | Exponential @ 1 Hz; 2 or 8 s response time |
| Alarms | High Rate: 15–250 bpm (5-bpm steps) Low Rate: 10–245 bpm (5-bpm steps) Asystole: R-R > 6 sec Lead Off / Check Lead |
| ECG Simulator | Built-in; 1 mV amplitude, 10–250 bpm |
| Display | 8.4″ TFT colour touch-screen LCD, 640×480 resolution |
| Synchronized Output | < 2 ms delay; R-R accuracy ±75 µs typical; Output impedance < 100 Ω |
| Trigger Output Settings | Pulse width: 1 / 50 / 100 / 150 ms Amplitude: 0–+5 V or –10 to +10 V Polarity: Positive or Negative |
| Interfaces / I/O | BNC Sync Output ¼″ ECG Analog Output DB-9 X-ray/Aux RS-232 Ethernet (10Base-T) USB Memory Stick |
| Optional Recorder | 2-trace direct-thermal strip chart recorder |
| Dimensions (H × W × D) | 22.14 × 23.50 × 15.49 cm (8.72″ × 9.25″ × 6.10″) |
| Weight | 2.54 kg (5.6 lb) |
| Power Requirements | 100–120 V or 200–230 V AC, 50/60 Hz; 45 VA max |
| Operating Conditions | 5°C–40°C; 0–90% RH (non-condensing); altitude –100 to +3,600 m; IPX1 |
| Storage Conditions | –40°C to +70°C; 5–95% RH; altitude –100 to +14,000 m |
| Regulatory Standards | IEC 60601-1, IEC 60601-2-27, AAMI EC-13, CE, ISO 13485 |
1X Used unit in stock. £990 for unit alone without stand.
Immediately available for dispatch, patient ready and this product is offered with a 6 month warranty period.
BD Asena / Alaris Replacement Carriage Assembly Kit P/N: 1000SP01107
Imed Gemini PC-1 Replacement Front Interface P/N: 10-3030-7
Alaris GS GH TVA PK Ente Rear Case Kit 1000SP01115
Mortara ELI350 ECG recorder with 17" LCD screen
Codan Argus 718V Infusion Pump
Spare Case Lower P5000 5000SP00018
Graseby Omnifuse Upper Case - New
Graseby 3000 Series Case Kits -New
Graseby Omnifuse Syringe Pumps
Philips TRIM PIM PCA Kit
Codan Argus 606 S Syringe Pump
Burdick ECG Patient Cable, 10 LD, IEC 