Datex-Ohmeda M-NMT module, in very good operational and physical condition, module’s actual photos displayed.
- Type: M-NMT-00-01
- Patient reedy
- Immediate despatch.
- Can add any of these cables/sensors at extra cost (see actual photos displayed):
- NMT Reusable Sensor Cable, 3.3m, in Good condition, Ref: 888414 (888415) add extra £180
- NMT Reusable Adult/Pediatric ElectroSensor, 0.3m, in Excellent condition, Ref: 888416, add extra £150
- NMT Reusable Adult MechanoSensor, in Excellent condition, Ref: 888418, add extra £150
- NMT Reusable Regional Block Adapter, 0.5m, in Excellent condition, Ref: 888417, add extra £100
- Description:
- NeuroMuscular Transmission Module. The M-NMT module is a single width plug-in module designed for
use with the S/5 Anesthesia and Compact Anesthesia Monitors. The module contains peripheral nerve stimulation and response measurement, which supports electromyography EMG. The module can also be used as a nerve locator for regional nerve blocking
with a regional block cable. However, in this case there is no response measurement.
- NeuroMuscular Transmission Module. The M-NMT module is a single width plug-in module designed for
- Specifications:
- General specifications
- Module size, W × D × H: 37 × 180 × 112 mm / 1.5 × 7.1 × 4.4 in
- Module weight: 0.37 kg /0.8 lbs
- Power consumption: 3.3 W
- Technical specifications:
- NMT
- Stimulation modes:
- Train of four (TOF)
- Double burst (3.3) (DBS)
- Single twitch (ST)
- 50 Hz tetanus + post tetanic count (PTC)
- Measurement intervals for TOF and DBS: Manual; 10 s, 12 s, 15 s, 20 s, 1 min, 5 min, 15 min
- Measurement intervals for ST Manual; 1 s, 10 s, 20 s
- Stimulation modes:
- Stimulator:
- Stimulus pulse: Square wave, constant current
- Pulse width: 100, 200 or 300 µs
- Stimulus current range: 10…70 mA with 5 mA steps
- Stimulus current accuracy: 10 % or ±3 mA whichever is the greater
- Max. load: 3 kΩ
- Max. voltage: 300 V
- Regional block mode:
- Stimulation modes: Single twitch
- Intervals: 1 s, 2 s, 3 s
- Stimulus pulse: Square wave, constant current
- Pulse width: 40 µs
- Stimulus current range: 0…5.0 mA with 0.1 mA steps
- Stimulus current accuracy: 20 % or 0.3 mA whichever is the greater
- NMT
- General specifications
Drager Spirolog FlowSensor
Datex-Ohmeda S/5 Compact Anesthesia
MIE FEMAL Superlite Connector
Maquet Oxygen Gas Module Type II
Drager Nebulizer
Drager expiratory patient block 8408220
Drager Sieve
Smith Medical PneuPAC BabyPAC 100 infant ventilator
New Pentax BS-LL1 Endoscope Lightsource (Ed.3.1)
Drager Oxylog Breathing Valve
Maquet potentiometer
Maquet/Siemens 24V 3m Power cable
Maquet/Siemens Comm. Cable 1.2M
Datex-Ohmeda ASSY, CYL SPLY PIN N2O BCG
Philips M3/M4 Series portable monitor 