Rigel PatSim200 Patient Simulator – New

Availability:

1 in stock


£1,140.00

1 in stock

Seaward Rigel PatSim200 Patient Simulator, its actual photo displayed.

  • Brand NEW with warranty.
  • Made in 2018
  • Supplied in its original box with standard accessories.
  • Can be Offered with a fresh calibration certificate at extra cost.

Features:

  • 12 lead NSR ECG simulation
  • Over 40 selectable Arrhythmias
  • Performance waveforms
  • Respiration simulation on lead I & II
  • Universal temperature simulation
  • Two channel IBP simulation
  • Fetal simulation
  • The new PatSim200 from Rigel was designed to make every patient simulation test you do quicker.
  • Unlike other Patient Simulator models, the PatSim200 uses a home and recall function to easily move between tests and store your most used sequences, no more clicking and scrolling through ‘tree style’ hierarchy to perform each test.
  • One of the most unique features of the PatSim200 is the ability to save 5 of your most used simulations and recall them at the touch of just 3 buttons.
  • The unit itself is compact, lightweight and the full color screen with easily altered high contrast low luminance lighting means adapting the unit for use in low lighting environments is simple. On top of these great features we’ve also ensured that the PatSim200 comes with universal ECG studs and mini DIN connectors so the cost to change your Patient Simulators over to the PatSim200 won’t spiral out of control – our unit will work with most legacy IBP and temperature cables you already have.

Technical Specifications:

Simulation Type
Full 12 lead ECG with independent outputs for each signal lead
Lead I 70%
Lead II 100%
Lead III 30%
Lead V1 24%
Lead V2 48%
Lead V3 100%
Lead V4 120%
Lead V5 112%
Lead V6 80%
ECG
Normal Sinus Rhythm
Rates 30, 40, 50, 60, 70, 80, 90, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300 BPM
Rate Accuracy ±1BPM or 1%
Amplitude (lead II) 0.05 to 0.45mV (0.05mV steps)
0.5 to 5.5mV (0.5mV steps)
Amplitude Accuracy ± 2%
ST Segments 18 selectable values, 8 elevated and 8 depressed -0.8 to +0.8mV in 0.1mV steps and +0.05mV and -0.05mV on Lead II
Neonatal Mode ECG R wave width is reduced to 40ms
ECG Performance Tests
Square Waves 2Hz, 0.125Hz
Triangle Wave 2Hz
Pulse 60bpm or 240bpm
Sine Waves 0.05, 0.5, 1, 10, 25, 30, 40, 50, 60, and 100Hz
Performance Amplitude 0.5 to 5.0mV in 0.5mV steps
Pacemaker
Simulated Rhythms Asynchronous at 75 BPM
Demand with frequent sinus beat
Demand with occasional sinus beat
A-V sequential
Non-capture
Non-function
Pulse Amplitude 1.0, 2.0, 5.0, 10.0mV
Accuracy ±10%
Width 0.1, 0.2, 0.5, 1.0, 2.0ms
Accuracy ± 5%
R-Wave Detector Test 30, 60, 80, 120, 200, 250 BPM
Haver-Triangle Width 8, 10, 12, 20, 40 ,60, 80, 100, 120, 140, 160, 180, 200ms
Performance Amplitude 0.5 to 5.0mV in 0.5mV steps
Arrhythmias
Ventricular Asystole
Bigeminy
Trigeminy
Ventricular fibrillation (coarse)
Ventricular fibrillation (fine)
Ventricular tachycardia
Supraventricular Atrial fibrillation (coarse)
Atrial fibrillation (fine)
Atrial flutter
Atrial tachycardia
Missing beat
Nodal rhythm
Paroxysmal atrial tachycardia
Sinus arrhythmia
Supraventricular tachycardia
Atrial Conduction First degree AV block
Left bundle branch block
Right bundle branch block
Second degree AV block – Mobitz I
Second degree AV block – Mobitz II
Third degree AV block
Premature Premature atrial contraction
Premature nodal contraction
Premature left ventricle contraction
Premature left ventricle contraction – early
Premature left ventricle contraction – R on T
Premature right ventricle contraction
Premature right ventricle contraction – early
Premature right ventricle contraction – R on T
Premature ventricular contraction – 6 / min
Premature ventricular contraction – 12 / min
Premature ventricular contraction – 24 / min
Premature ventricular contraction – frequent multifocal
Fetal Simulation
Maternal Heart Rate 80 BPM (Fixed)
Fetal Heart Rate (Selectable) 60, 90, 120, 140, 150, 210 and 240 BPM
Fetal Heart Rate (IUP) 140 BPM at beginning, then varying with pressure
Intrauterine-Pressure Waveforms Early deceleration, late deceleration and uniform acceleration
Simulation Period Manual, or 2, 3, or 5 minutes
Invasive Blood Pressure
Channels 2 channels
Static Pressure -10, -5, 0, 20, 40, 50, 60, 80,100, 150,160, 200, 240, 320, 400mmHg
Dynamic Simulation Arterial [ART] 120/80
Radial Artery [RA] 120/80
Left Ventricle [LV] 120/00
Right Ventricle [RV] 25/00
Right Atrium (central venous) [CVP] 15/10
Pulmonary Artery [PA] 25/10
Pulmonary Artery Wedge [PAW] 10/2
Left Atrium [LA] 14/4
Auto Sequence (Channel 1 only)
Cycle through simulations with 15 second step duration: Arterial [ART] 120/80
Radial Artery [RA] 120/80
Left Ventricle [LV] 120/00
Right Ventricle [RV] 25/00
Pulmonary Artery Wedge [PAW] 10/2
Pulmonary Artery [PA] 25/10
Right Atrium (central venous) [CVP] 15/10
Accuracy ± 1mmHg
Excitation voltage 2 to 16V
Impedance 350Ω Nominal
Simulated sensitivity 5μV/V/mmHg or 40μV/V/mmHg (user selectable)
Connector mini DIN style
Temperature
Simulation YSI 400 / 700A / 700B Static
Temperature Unit °C or °F, user selectable
Range 0.0, 24.0, 37.0, and 40.0°C
32.0, 75.2, 98.6, 104.0°F
Accuracy ± 0.1°C / °F
Connector Mini DIN style
Respiration
Rates Selectable values of 0, 5, 10, 15, 30, 40, 60, 80, 120, 180 brpm
Lead Selection Lead I and II, user selectable
Base Resistances 500, 1000, 1500 & 2000Ω
Accuracy ±5%
Resistance Variations 0.2, 0.5, 1.0, 3.0Ω
Accuracy ±10%
Apnoea Simulation Manual ON / OFF

General Specifications

Mains Power/Battery Info 3.7V 3900mAh 14.4WH Li-Ion battery
5V 1A USB micro-B power supply
100-240V ~ 50/60Hz 0.18A max.
Charge Time (new battery) Up to 3-4 hours
Battery Life Up to 6 hours, ~4 hours
Weight 0.70kg / 1.5lbs
Dimensions 180 x 150 x 55mm, 7.1 x 5.9 x 2.2″
Environmental Specifications
Operating Conditions 10 – 40°C (50 – 104°F) 0-90% RH – NC
Storage Environment -15 – 60°C (5 – 140°F) 0-90% RH – NC
Environmental Protection IP40
Part Number
PatSim200 404A920