Fluke QA-ES II Electrosurgical Analyzer

Availability:

1 in stock


£3,500.00

1 in stock

Fluke QA-ES II Electrosurgical Analyzer, in very good operational and physical condition, analyser’s actual photos displayed.

  • Made in USA
  • 115-140VAC 50/60Hz
  • Revision: 2.26
  • Fresh calibration certificate can be offered at extra cost.
  • Supplied with: Operating Manual
  • FEATURES:
    • QA-ES Series II analyzes electrosurgical units quickly and accurately.
    • Automatic power distribution measurement, including: power current, Peak-to-peak voltage (closed load only) and Crest-factor
    • Oscilloscope output
    • High-frequency leakage measurements with an accuracy of ±5 % of reading down to 20 mA guarantees reliable high-frequency leakage results.
    • A wide load-resistance range provides 128 user-selectable loads from 10 Ohm to 5200 Ohm, including very low loads for testing many of today’s ESUs.
    • Foot-switch output for triggering the ESU under test
    • An Ansur QA-ES software plug-in allows users to create and automatically run tests, capture data, and produce easy-to-read reports with a PC.
    • Large display
    • RS-232 and Centronic-printer interface 
  • Technical specifications:
    • Generator output:
      • Continuous operation: Continuous measurement of power, current, peak-to-peak voltage (closed load only), and crest factor
      • Single operation: Single measurement after the set delay time of the ESU output of power, current, peak-to-peak voltage (closed load only), and crest factor
      • Power distribution: Automatic measurement of power, current, peak-to-peak voltage (closed load only), and crest factor through a user-selectable load range
      • RF leakage current: Provides connections and load configurations to measure HF leakage from both grounded and isolated equipment
      • RECQM: Test the “return electrode control quality monitoring” using the QA-ES internal loads
    • Modes of operation: Manual or remote controlled (via Ansur)
    • Measurement: True-rms value of applied waveform
    • RMS bandwidth
      • 30 Hz to 10 MHz (-3 dB) for instrumentation only
      • 30 Hz to 2.5 MHz (-3 dB) with loads
    • Low frequency filter: 100 Hz filter to avoid low-frequency disturbance or interference
    • Current: 20 mA to 2200 mA
    • Current accuracy: 20 mA to 2200 mA ± 2 % of reading
    • Load resistance
      • 10 Ω to 2500 Ω in step of 25 Ω (@ dc)
      • 2500 Ω to 5200 Ω in step of 100 Ω (@ dc)
    • Additional fixed load: 200 Ω 400 W for 30 s; max 15 % duty cycle
    • Crest factor: The higher of the two peak voltage measurements is used for computation
    • Range: 1.4 to 16 (V peak/V rms)
    • Foot-switch output: The foot switch output can be used to trigger the electrosurgical unit
    • Peak-to-peak voltage
      • 0 kV to 10 kV (closed load only)
      • accuracy: ± 10 %
      • Note: Measurement is taken between the active and dispersive electrodes with closed load only.
    • Oscilloscope output: 5 V/A uncalibrated, 100 mA RF current minimum input
    • Ansur QA-ES Plug-In:
      • User-programmable test sequences:  Allows unlimited numbers of test sequences with user-programmable templates and test limits. These tests include power distribution test, output test, HF leakage, and RECQM verification
      • Remote control: All functions and tests in QA-ES may be performed from the PC
    • Storage and recall: Protocol formats and data may be stored, recalled, printed out, or transferred
    • Storage: 0 °C to 50 °C (32 °F to 122 °F)
    • Temperature Operating: 15 °C to 35 °C (59 °F to 95 °F)
    • Display: LCD graphic display
    • Alphanumeric format: 8 lines x 40 characters
    • Graphic mode: 240 x 64 pixel matrix
    • Display control: 5 F-keys, enter, cancel, control knob, and an encoder
    • Data input/outputs: Parallel printer port and bidirectional RS-232
    • Power: 115/230 V ac; 48 Hz to 66 Hz, 35 VA
    • Housing: Metal case
    • Dimensions (W x D x H): 39.5 cm x 34.2 cm x 13.2 cm (15.6 in x 13.5 in x 5.2 in)
    • Weight: 9.8 kg (21.6 lb