Metron QA-45 Defibrillator/Pacer Tester

×

Enquiry for: Metron QA-45 Defibrillator/Pacer Tester

    Availability:

    Out of stock


    SOLD OUT

    Metron QA-45 Defibrillator and Transcutaneous Pacer Analyser & Simulator, in very good physical and operational condition, analyzer’s actual photos displayed.

    • Code: 13020
    • Version: 2.6
    • Offered with 3 months warranty.
    • Immediate Dispatch.
    • Can be offered with Fresh calibration Certificate at extra cost
    • Features:
      • Energy and cardioversion measurement.
      • Peak voltage and current reading.
      • Storage and playback of output waveform.
      • 12 lead ECG simulation.
      • ECG, Performance and Arrhythmia simulation.
      • Automatic defibrillator test procedures. (Emergency scenarios using PRO-Soft QA-40M/45)
      • Pacemaker loads from 50 ohm to 2300 ohm.
      • Accuracy Tests: Amplitude, Rate, Pulse Width.
      • Demand Sensitivity Tests.
      • Refractory Period Tests: Sensed and Paced.
      • 60/50 Hz Immunity Test.
      • Pulse Energy.
      • Large graphic display.
      • RS-232C and Centronic printer interface.
      • Battery operation or AC adapter.
      • The QA-45 Defibrillator / Transcutaneous Pacemaker Analyzer is a precision instrument for testing defibrillators and external (transcutaneous) pacemakers. The built-in test procedures and extensive resistance loads for pacer testing, make the QA-45 a versatile test instrument and solid value.
      • The test results can either be written directly to a printer from the QA-45, or they may be transferred to PRO-Soft QA-40M/45 test automation software. With PRO-Soft, you can make your own test protocols, store protocols and test results to disk, and provide test data to update your equipment management database
    • Specifications:
      • DEFIBRILLATOR ANALYZER:
        • Energy Output Measurement:
          • High Range:
            • Voltage: <5000 V
            • Maximum Energy: 1000 J
            • Accuracy: ±2 % of reading for > 100 J ±2 J of reading for < 100 J
          • Low Range:
            • Voltage: < 1000 V
            • Maximum Energy: 50 J
            • Accuracy: ±2 % of reading for > 20 J ±2 J of reading for < 20 J
          • Load Resistance: 50 ohms ±1 %; non-inductive (< 1 µH)
          • Display Resolution: 0.1 J
          • Measurement Time Window: 100 ms
          • Absolute Max Peak Voltage: 6000 V
          • Absolute Max Peak Current: 120 A Pulse Width: 100 ms
          • Oscilloscope Output:
            • High Range: 1000:1 amplitude attenuation
            • Low Range: 200:1 amplitude attenuation
          • Waveform Storage / Playback: Discharge can be viewed via ECG outputs and paddles.
          • Output: 200:1 Time Base Expansion
          • Sync Time Measurements:
            • Timing Window: Starts – 40 ms at each R wave peak
            • Test Waveforms: All Waveform simulations available.
            • Delay Time Accuracy: ±1 ms
          • Charge Time Measurement: 0.1 to 99.9 seconds
      • ECG WAVEFORM SIMULATIONS:
        • ECG General:
          • Lead Configuration: 12-lead simulation. RL, RA, LA, LL, V1-6
          • Output Impedance:
            • Limb leads: 1000 ohms to RL
            • V Leads: 1000 ohms to RL
          • High Level Output: 1.0 V/mV of low level (lead II)
        • Manual ECG Performance Test:
          • Square wave: 2 Hz 1.0 mV p-p bipolar
          • DC Pulse: 4.0 seconds 1.0 mV
          • Sine waves: 0.1, 0.2, 0.5, 10, 40, 50, 60, 100 Hz
          • Triangle wave: 2.0 Hz
          • Amplitudes: 0.5, 1.0, 1.5, 2.0 mV (Lead II)
          • Amplitude accuracy : ±5 % (Lead II 1.0 mV)
        • ECG Performance Test:
          • Gain/Damping: 2 Hz square wave
          • Frequency Response: Low Frequency: 4 second DC pulse
          • Band Pass: 10 Hz sine
          • Monitor: -3dB point: 40 Hz sine
          • Power Line Notch Filter: 50 Hz sine
          • Linearity: 2 Hz triangle wave
          • Normal Sinus: Rates: 30, 60, 80, 120, 180, 240 & 300 BPM
          • Rate accuracy: ±1 % of selection
          • Amplitudes: 0.5, 1.0, 1.5, 2.0 mV (Lead II)
          • Amplitude accuracy: ±5 % (Lead II 1.0 mV)
        • AUTOMATIC ECG RATE TEST:
          • Arrhythmia Selections:
            • Atrial Fibrillation 1 & 2
            • Premature Atrial Contraction
            • PVC
            • Early PVC
            • R on T PVC
            • Multifocal PVCs
            • Bigeminy
            • Bigeminy Run of 5 PVCs
            • Ventricular Tachycardia
            • Ventricular Fibrillation
            • Second Degree Type 2
            • Right Bundle Branch Block
      • TRANS. PACEMAKER ANALYZER:
        • Test Load Range:
          • 50 to 2300 ohms in step of:
            • – 50 ohm up to 200 ohms
            • – 100ohm from 200 up to 2300 ohms
        • Accuracy:
          • 50 – 1300 ohm ±1 %
          • 1400 – 2300 ohm ±1.5 %
        • Oscilloscope Output:
          • 50 – 150 ohm10.24:1amplitude attenuation
          • 200 – 500 ohm41:1 amplitude attenuation
          • 600 – 2300 ohm164:1 amplitude attenuation
        • Pulse Measurements:
          • Amplitude: 4 to 300 mA (100 ohm load)
          • Accuracy: ±5 % or ±0.5 mA
          • Max. amplitude: 300 mA all loads
          • Rate: 30 to 800 ppm
          • Accuracy: ±1 % or 2 ppm
          • Pulse Width: 0.6 to 80 ms
          • Accuracy: ±1 % or ±0.3 ms
        • Demand Sensitivity Test:
          • Waveforms: Square(SQR), Triangle(TRI), and Haversine (SSQ)
        • ECG Output:
          • Amplitude: 0 – 4 mV
          • Resolution: 40 µV
        • Pacer Input (Load dependent):
          • Amplitude (50 ohm): 0 – 10 mV
          • Resolution (50 ohm): 40 µV
          • Amplitude: (³500 ohm): 0 – 100 mV
          • Resolution: (³500 ohm): 1 mV
        • Defib. Pads:
          • Amplitude: 0 – 10 mV
          • Resolution: 0.1 mV
        • Waveform width: 10, 25, 40, 100 and 200 ms
        • Pacer rate: 30 to 120 ppm
        • Immunity Test: 50/60 Hz Interference Signal
        • ECG Output: 0 – 4 mV peak in step of 0.4 mV
        • Pacer Input (Load dependent):
          • 0 – 10 mV peak in step of 1 mV (50 ohm)
          • 0 – 100 mV peak in step of 10 mV (³500 ohm)
        • Defib. Pads: 0 – 10 mV peak in step of 1 mV
        • Refractory Period Measurement:
          • 20 to 500 ms (both Pacing and Sensing)
          • Accuracy: ±2 ms
      • GENERAL INFORMATION
        • Temperature Range:
          • +15°C to +35°C when operating.
          • 0°C to +50°C in storage.
        • Display:
          • Type: LCD graphic display.
          • Alphanumeric format: 8 lines by 40 characters.
        • Data Input/Outputs (2):
          • Parallel printerport (1); Bi-Directional
          • RS-232C (1) for Computer control.
        • Power:
          • 2 x 9 Volt Alkaline Battery.
          • 240 VAC Battery Eliminator.
          • 115 VAC Battery EL. For US.
        • Housing: High impact plastic case.
        • DIMENSIONS: D x W x H: 28.0 cm x 24.8 cm x 9.8 cm. 11 in x 9.8 in x 3.9 in.
        • Weight: 1.85 kg / 4.1 lbs. with battery.
        • Recommended Printers: HP Deskjet, Canon Bubble Jet, or compatible