Metron QA-45 Defibrillator/Pacer Tester

Availability:

1 in stock


£1,480.00

1 in stock

Metron QA-45 Defibrillator and Transcutaneous Pacer Analyser & Simulator, in very good physical and operational condition, analyzer’s actual photos displayed.

  • Code: 13020
  • Version: 2.6
  • Offered with 3 months warranty.
  • Immediate Dispatch.
  • Can be offered with Fresh calibration Certificate at extra cost
  • Features:
    • Energy and cardioversion measurement.
    • Peak voltage and current reading.
    • Storage and playback of output waveform.
    • 12 lead ECG simulation.
    • ECG, Performance and Arrhythmia simulation.
    • Automatic defibrillator test procedures. (Emergency scenarios using PRO-Soft QA-40M/45)
    • Pacemaker loads from 50 ohm to 2300 ohm.
    • Accuracy Tests: Amplitude, Rate, Pulse Width.
    • Demand Sensitivity Tests.
    • Refractory Period Tests: Sensed and Paced.
    • 60/50 Hz Immunity Test.
    • Pulse Energy.
    • Large graphic display.
    • RS-232C and Centronic printer interface.
    • Battery operation or AC adapter.
    • The QA-45 Defibrillator / Transcutaneous Pacemaker Analyzer is a precision instrument for testing defibrillators and external (transcutaneous) pacemakers. The built-in test procedures and extensive resistance loads for pacer testing, make the QA-45 a versatile test instrument and solid value.
    • The test results can either be written directly to a printer from the QA-45, or they may be transferred to PRO-Soft QA-40M/45 test automation software. With PRO-Soft, you can make your own test protocols, store protocols and test results to disk, and provide test data to update your equipment management database
  • Specifications:
    • DEFIBRILLATOR ANALYZER:
      • Energy Output Measurement:
        • High Range:
          • Voltage: <5000 V
          • Maximum Energy: 1000 J
          • Accuracy: ±2 % of reading for > 100 J ±2 J of reading for < 100 J
        • Low Range:
          • Voltage: < 1000 V
          • Maximum Energy: 50 J
          • Accuracy: ±2 % of reading for > 20 J ±2 J of reading for < 20 J
        • Load Resistance: 50 ohms ±1 %; non-inductive (< 1 µH)
        • Display Resolution: 0.1 J
        • Measurement Time Window: 100 ms
        • Absolute Max Peak Voltage: 6000 V
        • Absolute Max Peak Current: 120 A Pulse Width: 100 ms
        • Oscilloscope Output:
          • High Range: 1000:1 amplitude attenuation
          • Low Range: 200:1 amplitude attenuation
        • Waveform Storage / Playback: Discharge can be viewed via ECG outputs and paddles.
        • Output: 200:1 Time Base Expansion
        • Sync Time Measurements:
          • Timing Window: Starts – 40 ms at each R wave peak
          • Test Waveforms: All Waveform simulations available.
          • Delay Time Accuracy: ±1 ms
        • Charge Time Measurement: 0.1 to 99.9 seconds
    • ECG WAVEFORM SIMULATIONS:
      • ECG General:
        • Lead Configuration: 12-lead simulation. RL, RA, LA, LL, V1-6
        • Output Impedance:
          • Limb leads: 1000 ohms to RL
          • V Leads: 1000 ohms to RL
        • High Level Output: 1.0 V/mV of low level (lead II)
      • Manual ECG Performance Test:
        • Square wave: 2 Hz 1.0 mV p-p bipolar
        • DC Pulse: 4.0 seconds 1.0 mV
        • Sine waves: 0.1, 0.2, 0.5, 10, 40, 50, 60, 100 Hz
        • Triangle wave: 2.0 Hz
        • Amplitudes: 0.5, 1.0, 1.5, 2.0 mV (Lead II)
        • Amplitude accuracy : ±5 % (Lead II 1.0 mV)
      • ECG Performance Test:
        • Gain/Damping: 2 Hz square wave
        • Frequency Response: Low Frequency: 4 second DC pulse
        • Band Pass: 10 Hz sine
        • Monitor: -3dB point: 40 Hz sine
        • Power Line Notch Filter: 50 Hz sine
        • Linearity: 2 Hz triangle wave
        • Normal Sinus: Rates: 30, 60, 80, 120, 180, 240 & 300 BPM
        • Rate accuracy: ±1 % of selection
        • Amplitudes: 0.5, 1.0, 1.5, 2.0 mV (Lead II)
        • Amplitude accuracy: ±5 % (Lead II 1.0 mV)
      • AUTOMATIC ECG RATE TEST:
        • Arrhythmia Selections:
          • Atrial Fibrillation 1 & 2
          • Premature Atrial Contraction
          • PVC
          • Early PVC
          • R on T PVC
          • Multifocal PVCs
          • Bigeminy
          • Bigeminy Run of 5 PVCs
          • Ventricular Tachycardia
          • Ventricular Fibrillation
          • Second Degree Type 2
          • Right Bundle Branch Block
    • TRANS. PACEMAKER ANALYZER:
      • Test Load Range:
        • 50 to 2300 ohms in step of:
          • – 50 ohm up to 200 ohms
          • – 100ohm from 200 up to 2300 ohms
      • Accuracy:
        • 50 – 1300 ohm ±1 %
        • 1400 – 2300 ohm ±1.5 %
      • Oscilloscope Output:
        • 50 – 150 ohm10.24:1amplitude attenuation
        • 200 – 500 ohm41:1 amplitude attenuation
        • 600 – 2300 ohm164:1 amplitude attenuation
      • Pulse Measurements:
        • Amplitude: 4 to 300 mA (100 ohm load)
        • Accuracy: ±5 % or ±0.5 mA
        • Max. amplitude: 300 mA all loads
        • Rate: 30 to 800 ppm
        • Accuracy: ±1 % or 2 ppm
        • Pulse Width: 0.6 to 80 ms
        • Accuracy: ±1 % or ±0.3 ms
      • Demand Sensitivity Test:
        • Waveforms: Square(SQR), Triangle(TRI), and Haversine (SSQ)
      • ECG Output:
        • Amplitude: 0 – 4 mV
        • Resolution: 40 µV
      • Pacer Input (Load dependent):
        • Amplitude (50 ohm): 0 – 10 mV
        • Resolution (50 ohm): 40 µV
        • Amplitude: (³500 ohm): 0 – 100 mV
        • Resolution: (³500 ohm): 1 mV
      • Defib. Pads:
        • Amplitude: 0 – 10 mV
        • Resolution: 0.1 mV
      • Waveform width: 10, 25, 40, 100 and 200 ms
      • Pacer rate: 30 to 120 ppm
      • Immunity Test: 50/60 Hz Interference Signal
      • ECG Output: 0 – 4 mV peak in step of 0.4 mV
      • Pacer Input (Load dependent):
        • 0 – 10 mV peak in step of 1 mV (50 ohm)
        • 0 – 100 mV peak in step of 10 mV (³500 ohm)
      • Defib. Pads: 0 – 10 mV peak in step of 1 mV
      • Refractory Period Measurement:
        • 20 to 500 ms (both Pacing and Sensing)
        • Accuracy: ±2 ms
    • GENERAL INFORMATION
      • Temperature Range:
        • +15°C to +35°C when operating.
        • 0°C to +50°C in storage.
      • Display:
        • Type: LCD graphic display.
        • Alphanumeric format: 8 lines by 40 characters.
      • Data Input/Outputs (2):
        • Parallel printerport (1); Bi-Directional
        • RS-232C (1) for Computer control.
      • Power:
        • 2 x 9 Volt Alkaline Battery.
        • 240 VAC Battery Eliminator.
        • 115 VAC Battery EL. For US.
      • Housing: High impact plastic case.
      • DIMENSIONS: D x W x H: 28.0 cm x 24.8 cm x 9.8 cm. 11 in x 9.8 in x 3.9 in.
      • Weight: 1.85 kg / 4.1 lbs. with battery.
      • Recommended Printers: HP Deskjet, Canon Bubble Jet, or compatible