<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Biomedical Test Equipment &#8211; Robin Medical Ltd</title>
	<atom:link href="https://robinmedical.co.uk/product-category/biomedical-test-equipment/feed/" rel="self" type="application/rss+xml" />
	<link>https://robinmedical.co.uk</link>
	<description>Welcome to the Robin Medical Online Store!</description>
	<lastBuildDate>Fri, 03 Apr 2026 19:04:22 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.5</generator>
	<item>
		<title>Ultramedic IDA-1 Infusion pumps Analyzer</title>
		<link>https://robinmedical.co.uk/product/bio-tek-instruments-ida-1-infusion-device-analyzer/</link>
		
		<dc:creator><![CDATA[r@bnm32_admin]]></dc:creator>
		<pubDate>Tue, 09 Dec 2025 16:00:52 +0000</pubDate>
				<guid isPermaLink="false">https://robinmedical.co.uk/?post_type=product&#038;p=18085</guid>

					<description><![CDATA[<p>Ultramedic MASAR IDA-1 Infusion pumps Analyzer, in very good operating condition, its actual photo displayed. Can be offered with New calibration certificate at extra cost. The IDA-1 is a One-Channel</p>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/bio-tek-instruments-ida-1-infusion-device-analyzer/">Ultramedic IDA-1 Infusion pumps Analyzer</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="color: #000000;"><strong><span style="color: #0000ff;">Ultramedic MASAR IDA-1 Infusion pumps Analyzer</span>, in very good operating condition, its actual photo displayed.</strong></span></p>
<ul>
<li><span style="color: #000000;"><strong>Can be offered with New calibration certificate at extra cost.</strong></span></li>
<li></li>
<li><span style="color: #000000;"><strong>The IDA-1 is a One-Channel Infusion Device Analyzer, mains operated that allows for speedy verification of infusion </strong></span><span style="color: #000000;"><strong>device performance. The IDA-1 measures the flow rate and volume delivered, and the pressure generated in occlusions </strong></span><span style="color: #000000;"><strong>or blockages of the fluid line. </strong></span></li>
</ul>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/bio-tek-instruments-ida-1-infusion-device-analyzer/">Ultramedic IDA-1 Infusion pumps Analyzer</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Clinical Dynamics &#8211; SmartArm NIBP Simulator GX-2</title>
		<link>https://robinmedical.co.uk/product/clinical-dynamics-smartarm-nibp-simulator/</link>
		
		<dc:creator><![CDATA[r@bnm32_admin]]></dc:creator>
		<pubDate>Thu, 02 Oct 2025 14:45:11 +0000</pubDate>
				<guid isPermaLink="false">https://robinmedical.co.uk/?post_type=product&#038;p=17305</guid>

					<description><![CDATA[<p>The Clinical Dynamics SmartArm NIBP Simulator GX-2 is a benchtop, microprocessor-controlled medical device tester used by biomedical technicians to accurately test and calibrate Non-Invasive Blood Pressure (NIBP) patient monitors. The simulator</p>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/clinical-dynamics-smartarm-nibp-simulator/">Clinical Dynamics &#8211; SmartArm NIBP Simulator GX-2</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="ng-tns-c555498503-80">
<section id="processing-state-3" class="processing-state_container ng-tns-c555498503-80 is-gpi-avatar ng-trigger ng-trigger-processingStateShowHide ng-star-inserted is-done-processing">
<div id="processing-state-3-summary" class="processing-state_details ng-trigger ng-trigger-menuExpansion ng-tns-c555498503-80 is-gpi-avatar ng-star-inserted" aria-hidden="true">
<div class="tool-summary ng-tns-c555498503-80">
<div class="tool-summary-message ng-tns-c555498503-80 gds-body-l ng-star-inserted">
<div class="ng-tns-c555498503-80"><span style="color: #000000;">The <span style="color: #0000ff;"><b>Clinical Dynamics SmartArm NIBP Simulator GX-2</b></span> is a benchtop, microprocessor-controlled medical device tester used by biomedical technicians to accurately test and calibrate Non-Invasive Blood Pressure (NIBP) patient monitors. The simulator works by generating highly accurate, repeatable pressure pulses to mimic the oscillations a real patient&#8217;s artery would produce under a blood pressure cuff.</span></div>
</div>
</div>
</div>
</section>
</div>
<div class="response-content ng-tns-c1802502583-79">
<div id="model-response-message-contentr_d56d095866d7f78d" class="markdown markdown-main-panel enable-updated-hr-color" dir="ltr">
<p><span style="color: #000000;">It is a portable unit that features built-in supports (mandrels) for both adult and neonatal cuffs, making it a comprehensive tool for NIBP monitor testing</span></p>
<hr data-start="1274" data-end="1277" />
<h2 data-start="1279" data-end="1308"><span style="color: #000000;">Technical Specifications:</span></h2>
<div class="_tableContainer_1rjym_1">
<div class="group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1310" data-end="3086">
<thead data-start="1310" data-end="1347">
<tr data-start="1310" data-end="1347">
<th data-start="1310" data-end="1326" data-col-size="sm"><span style="color: #000000;"><strong data-start="1312" data-end="1325">Parameter:</strong></span></th>
<th data-start="1326" data-end="1347" data-col-size="lg"><span style="color: #000000;"><strong data-start="1328" data-end="1345">Specification:</strong></span></th>
</tr>
</thead>
<tbody data-start="1426" data-end="3086">
<tr data-start="1426" data-end="1478">
<td data-start="1426" data-end="1445" data-col-size="sm"><span style="color: #000000;"><strong data-start="1428" data-end="1444">Manufacturer</strong></span></td>
<td data-start="1445" data-end="1478" data-col-size="lg"><span style="color: #000000;">Clinical Dynamics Corporation</span></td>
</tr>
<tr data-start="1479" data-end="1566">
<td data-start="1479" data-end="1501" data-col-size="sm"><span style="color: #000000;"><strong data-start="1481" data-end="1500">Product / Model</strong></span></td>
<td data-start="1501" data-end="1566" data-col-size="lg"><span style="color: #000000;">SmartArm NIBP Simulator GX-2</span></td>
</tr>
<tr data-start="1567" data-end="1681">
<td data-start="1567" data-end="1596" data-col-size="sm"><span style="color: #000000;"><strong data-start="1569" data-end="1595">Dimensions (W × H × D)</strong></span></td>
<td data-start="1596" data-end="1681" data-col-size="lg"><span style="color: #000000;">7.75″ × 4.75″ × 12.0″ (~197 × 121 × 305 mm) </span></td>
</tr>
<tr data-start="1682" data-end="1780">
<td data-start="1682" data-end="1695" data-col-size="sm"><span style="color: #000000;"><strong data-start="1684" data-end="1694">Weight</strong></span></td>
<td data-start="1695" data-end="1780" data-col-size="lg"><span style="color: #000000;">~8.75 lb (with internal battery) (~3.97 kg) </span></td>
</tr>
<tr data-start="1781" data-end="1920">
<td data-start="1781" data-end="1801" data-col-size="sm"><span style="color: #000000;"><strong data-start="1783" data-end="1800">Input / Power</strong></span></td>
<td data-start="1801" data-end="1920" data-col-size="lg"><span style="color: #000000;">External adaptor: 100–240 V AC to 24 V DC; internal NiMH battery (optionally)</span></td>
</tr>
<tr data-start="1921" data-end="2020">
<td data-start="1921" data-end="1942" data-col-size="sm"><span style="color: #000000;"><strong data-start="1923" data-end="1941">Pressure Range</strong></span></td>
<td data-start="1942" data-end="2020" data-col-size="lg"><span style="color: #000000;">Up to ~410 mmHg (simulate pressures) </span></td>
</tr>
<tr data-start="2021" data-end="2128">
<td data-start="2021" data-end="2036" data-col-size="sm"><span style="color: #000000;"><strong data-start="2023" data-end="2035">Accuracy</strong></span></td>
<td data-start="2036" data-end="2128" data-col-size="lg"><span style="color: #000000;">±0.5 mmHg resolution / traceable to NIST standards </span></td>
</tr>
<tr data-start="2129" data-end="2253">
<td data-start="2129" data-end="2152" data-col-size="sm"><span style="color: #000000;"><strong data-start="2131" data-end="2151">Simulation Modes</strong></span></td>
<td data-start="2152" data-end="2253" data-col-size="lg"><span style="color: #000000;">Leak Test, Over-Pressure Test, BP Test (adult &amp; neonatal) <span class="" data-state="closed"><span class="ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]" data-testid="webpage-citation-pill"><span class="relative start-0 bottom-0 flex h-full w-full items-center"><span class="flex h-4 w-full items-center justify-between"><span class="max-w-[15ch] grow truncate overflow-hidden text-center">cdn.websites.hibu.com</span></span></span></span></span></span></td>
</tr>
<tr data-start="2254" data-end="2415">
<td data-start="2254" data-end="2281" data-col-size="sm"><span style="color: #000000;"><strong data-start="2256" data-end="2280">Heartbeat / HR Range</strong></span></td>
<td data-start="2281" data-end="2415" data-col-size="lg"><span style="color: #000000;">Standard presets (e.g. 75 BPM adult, 120 BPM neonatal) plus adjustable 30–240 BPM in steps </span></td>
</tr>
<tr data-start="2416" data-end="2561">
<td data-start="2416" data-end="2430" data-col-size="sm"><span style="color: #000000;"><strong data-start="2418" data-end="2429">Display</strong></span></td>
<td data-start="2430" data-end="2561" data-col-size="lg"><span style="color: #000000;">High-resolution graphical LCD display (320 × 240) with real-time cuff pressure waveform</span></td>
</tr>
<tr data-start="2562" data-end="2671">
<td data-start="2562" data-end="2582" data-col-size="sm"><span style="color: #000000;"><strong data-start="2564" data-end="2581">Cuff Supports</strong></span></td>
<td data-start="2582" data-end="2671" data-col-size="lg"><span style="color: #000000;">Built-in adult &amp; neonatal mandrels / supports</span></td>
</tr>
<tr data-start="2672" data-end="2819">
<td data-start="2672" data-end="2703" data-col-size="sm"><span style="color: #000000;"><strong data-start="2674" data-end="2702">Serial / Parallel Output</strong></span></td>
<td data-start="2703" data-end="2819" data-col-size="lg"><span style="color: #000000;">RS-232 serial control (remote commands) and parallel printing capability</span></td>
</tr>
</tbody>
</table>
<p><span style="color: #000000;"><strong>1X Used unit in stock.<br />
</strong><strong>Immediately available for dispatch and this product is offered with a 3 month warranty period.<br />
Calibration can be requested separately, in order to make it compliant with medical use.</strong></span></p>
</div>
</div>
</div>
</div>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/clinical-dynamics-smartarm-nibp-simulator/">Clinical Dynamics &#8211; SmartArm NIBP Simulator GX-2</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>IngMar Medical Adult/Pediatric Demonstration Lung Model</title>
		<link>https://robinmedical.co.uk/product/ingmar-medical-adult-pediatric-demonstration-lung-model/</link>
		
		<dc:creator><![CDATA[r@bnm32_admin]]></dc:creator>
		<pubDate>Thu, 02 Oct 2025 14:39:38 +0000</pubDate>
				<guid isPermaLink="false">https://robinmedical.co.uk/?post_type=product&#038;p=17303</guid>

					<description><![CDATA[<p>The IngMar Medical Adult/Pediatric Demonstration Lung Model is a passive, two-bellows lung simulator engineered for ventilator training, teaching, and demonstrations. It enables instructors to simulate a wide range of respiratory</p>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/ingmar-medical-adult-pediatric-demonstration-lung-model/">IngMar Medical Adult/Pediatric Demonstration Lung Model</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p data-start="204" data-end="974"><span style="color: #000000;">The <span style="color: #0000ff;"><strong data-start="208" data-end="267">IngMar Medical Adult/Pediatric Demonstration Lung Model</strong></span> is a passive, two-bellows lung simulator engineered for ventilator training, teaching, and demonstrations. It enables instructors to simulate a wide range of respiratory scenarios—such as variable compliance, resistances, and leaks—while students observe real ventilator waveforms in a safe, controlled environment. The unit offers straightforward control knobs for resistance, leak, and compliance adjustments and connects via a standard <span style="color: #0000ff;"><strong>15 mm ISO port</strong></span> compatible with ventilator circuits. This training lung model allows educators to visually and mechanically demonstrate ventilator-patient interactions, pathologies like air trapping or tube leaks, and spontaneous breath triggering by manual actuation.</span></p>
<hr data-start="976" data-end="979" />
<h2 data-start="981" data-end="1010"><span style="color: #000000;">Technical Specifications:</span></h2>
<div class="_tableContainer_1rjym_1">
<div class="group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1012" data-end="2624">
<thead data-start="1012" data-end="1057">
<tr data-start="1012" data-end="1057">
<th data-start="1012" data-end="1028" data-col-size="sm"><span style="color: #000000;"><strong data-start="1014" data-end="1027">Parameter:</strong></span></th>
<th data-start="1028" data-end="1057" data-col-size="lg"><span style="color: #000000;"><strong data-start="1030" data-end="1055">Specification / Range:</strong></span></th>
</tr>
</thead>
<tbody data-start="1068" data-end="2624">
<tr data-start="1068" data-end="1193">
<td data-start="1068" data-end="1089" data-col-size="sm"><span style="color: #000000;"><strong data-start="1070" data-end="1088">Simulator Type</strong></span></td>
<td data-start="1089" data-end="1193" data-col-size="lg"><span style="color: #000000;">Passive lung simulator, two independent compartments (bellows) </span></td>
</tr>
<tr data-start="1194" data-end="1279">
<td data-start="1194" data-end="1231" data-col-size="sm"><span style="color: #000000;"><strong data-start="1196" data-end="1230">Maximum Volume per Compartment</strong></span></td>
<td data-col-size="lg" data-start="1231" data-end="1279"><span style="color: #000000;">~<span class="" data-state="closed"><span class="ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]" data-testid="webpage-citation-pill"><span class="relative start-0 bottom-0 flex h-full w-full items-center"><span class="flex h-4 w-full items-center justify-between"><span class="max-w-[15ch] grow truncate overflow-hidden text-center"><span class="math-inline"><span class="katex"><span class="katex-html" aria-hidden="true"><span class="base"><span class="mord">2</span><span class="mbin">×</span></span><span class="base"><span class="mord">1.0</span><span class="mord text"><span class="mord"> L</span></span></span></span></span></span> Nominal (Two separate bellows)</span></span></span></span></span></span></td>
</tr>
<tr data-start="1280" data-end="1389">
<td data-start="1280" data-end="1306" data-col-size="sm"><span style="color: #000000;"><strong data-start="1282" data-end="1305">Compliance Settings</strong></span></td>
<td data-start="1306" data-end="1389" data-col-size="lg"><span style="color: #000000;"><span class="math-inline"><span class="katex"><span class="katex-html" aria-hidden="true"><span class="base"><span class="mord">18</span><span class="mord text"><span class="mord"> to </span></span><span class="mord">80</span><span class="mord text"><span class="mord"> mL</span></span><span class="mord">/</span><span class="mord"><span class="mord text">cmH</span><span class="msupsub"><span class="vlist-t vlist-t2"><span class="vlist-r"><span class="vlist"><span class=""><span class="sizing reset-size6 size3 mtight"><span class="mord mtight">2</span></span></span></span><span class="vlist-s">​</span></span></span></span></span><span class="mord text"><span class="mord">O</span></span></span></span></span></span> overall range (adjustable via quick-acting grip latches)</span></td>
</tr>
<tr data-start="1390" data-end="1509">
<td data-start="1390" data-end="1416" data-col-size="sm"><span style="color: #000000;"><strong data-start="1392" data-end="1415">Resistance Settings</strong></span></td>
<td data-col-size="lg" data-start="1416" data-end="1509"><span style="color: #000000;">Switch-selectable: <span class="math-inline"><span class="katex"><span class="katex-html" aria-hidden="true"><span class="base"><span class="mord">15</span></span></span></span></span>, <span class="math-inline"><span class="katex"><span class="katex-html" aria-hidden="true"><span class="base"><span class="mord">25</span></span></span></span></span>, <span class="math-inline"><span class="katex"><span class="katex-html" aria-hidden="true"><span class="base"><span class="mord">50</span><span class="mord"><span class="mord text"> cmH</span><span class="msupsub"><span class="vlist-t vlist-t2"><span class="vlist-r"><span class="vlist"><span class=""><span class="sizing reset-size6 size3 mtight"><span class="mord mtight">2</span></span></span></span><span class="vlist-s">​</span></span></span></span></span><span class="mord text"><span class="mord">O</span></span><span class="mord">/</span><span class="mord text"><span class="mord">L</span></span><span class="mord">/</span><span class="mord text"><span class="mord">s</span></span></span></span></span></span></span></td>
</tr>
<tr data-start="1510" data-end="1703">
<td data-start="1510" data-end="1532" data-col-size="sm"><span style="color: #000000;"><strong data-start="1512" data-end="1531">Leak Simulation</strong></span></td>
<td data-start="1532" data-end="1703" data-col-size="lg"><span style="color: #000000;">Switch-selectable for ET-tube and lung leak: <span class="math-inline"><span class="katex"><span class="katex-html" aria-hidden="true"><span class="base"><span class="mord">10</span></span></span></span></span>, <span class="math-inline"><span class="katex"><span class="katex-html" aria-hidden="true"><span class="base"><span class="mord">16</span></span></span></span></span>, <span class="math-inline"><span class="katex"><span class="katex-html" aria-hidden="true"><span class="base"><span class="mord">25</span><span class="mord text"><span class="mord"> L</span></span><span class="mord">/</span><span class="mord text"><span class="mord">min</span></span></span></span></span></span> at <span class="math-inline"><span class="katex"><span class="katex-html" aria-hidden="true"><span class="base"><span class="mord">40</span><span class="mord"><span class="mord text"> cmH</span><span class="msupsub"><span class="vlist-t vlist-t2"><span class="vlist-r"><span class="vlist"><span class=""><span class="sizing reset-size6 size3 mtight"><span class="mord mtight">2</span></span></span></span><span class="vlist-s">​</span></span></span></span></span><span class="mord text"><span class="mord">O</span></span></span></span></span></span></span></td>
</tr>
<tr data-start="1704" data-end="1862">
<td data-start="1704" data-end="1732" data-col-size="sm"><span style="color: #000000;"><strong>Ventilator Connection</strong></span></td>
<td data-col-size="lg" data-start="1732" data-end="1862"><span style="color: #000000;">Standard <span class="math-inline"><span class="katex"><span class="katex-html" aria-hidden="true"><span class="base"><span class="mord">15</span><span class="mord text"><span class="mord"> mm</span></span></span></span></span></span> ISO ET-tube connector</span></td>
</tr>
<tr data-start="1863" data-end="1960">
<td data-start="1863" data-end="1890" data-col-size="sm"><span style="color: #000000;"><strong data-start="1963" data-end="1995">Simulated Spontaneous Effort</strong></span></td>
<td data-start="1890" data-end="1960" data-col-size="lg"><span style="color: #000000;">Manual: by gently lifting bellows to simulate patient-initiated breath</span></td>
</tr>
<tr data-start="1961" data-end="2108">
<td data-start="1961" data-end="1996" data-col-size="sm"><span style="color: #000000;"><strong data-start="2111" data-end="2133">Overall Dimensions</strong></span></td>
<td data-start="1996" data-end="2108" data-col-size="lg"><span style="color: #000000;"><span class="math-inline"><span class="katex"><span class="katex-html" aria-hidden="true"><span class="base"><span class="mord">291</span><span class="mbin">×</span></span><span class="base"><span class="mord">248</span><span class="mbin">×</span></span><span class="base"><span class="mord">165</span><span class="mord text"><span class="mord"> mm</span></span></span></span></span></span> (<span class="math-inline"><span class="katex"><span class="katex-html" aria-hidden="true"><span class="base"><span class="mord">11.5</span><span class="mbin">×</span></span><span class="base"><span class="mord">9.8</span><span class="mbin">×</span></span><span class="base"><span class="mord">6.5</span><span class="mord text"><span class="mord"> inches</span></span></span></span></span></span>)</span></td>
</tr>
<tr data-start="2109" data-end="2230">
<td data-start="2109" data-end="2134" data-col-size="sm"><span style="color: #000000;"><strong data-start="2233" data-end="2243">Weight</strong></span></td>
<td data-start="2134" data-end="2230" data-col-size="lg"><span style="color: #000000;"> ~<span class="math-inline"><span class="katex"><span class="katex-html" aria-hidden="true"><span class="base"><span class="mord">7</span><span class="mord text"><span class="mord"> kg</span></span></span></span></span></span> (<span class="math-inline"><span class="katex"><span class="katex-html" aria-hidden="true"><span class="base"><span class="mord">15.4</span><span class="mord text"><span class="mord"> lb</span></span></span></span></span></span>) to <span class="math-inline"><span class="katex"><span class="katex-html" aria-hidden="true"><span class="base"><span class="mord">8</span><span class="mord text"><span class="mord"> kg</span></span></span></span></span></span> (<span class="math-inline"><span class="katex"><span class="katex-html" aria-hidden="true"><span class="base"><span class="mord">17.6</span><span class="mord text"><span class="mord"> lb</span></span></span></span></span></span>) (depending on options)</span></td>
</tr>
<tr data-start="2231" data-end="2345">
<td data-start="2231" data-end="2244" data-col-size="sm"><span style="color: #000000;"><strong data-start="2348" data-end="2370">Material / Housing</strong></span></td>
<td data-start="2244" data-end="2345" data-col-size="lg"><span style="color: #000000;">Aluminium case with lid, knobs, and internal bellows assembly</span></td>
</tr>
<tr data-start="2346" data-end="2475">
<td data-start="2346" data-end="2371" data-col-size="sm"><span style="color: #000000;"><strong data-start="2478" data-end="2497">Cleaning / Care</strong></span></td>
<td data-start="2371" data-end="2475" data-col-size="lg"><span style="color: #000000;">Wipe outer surfaces with mild detergent; not intended to be immersed or sterilized</span></td>
</tr>
<tr data-start="2476" data-end="2624">
<td data-start="2476" data-end="2498" data-col-size="sm"></td>
<td data-start="2498" data-end="2624" data-col-size="lg"></td>
</tr>
</tbody>
</table>
<ul>
<li><span style="color: #000000;"><strong>2 x Units in stock. </strong></span></li>
<li><span style="color: #000000;"><strong>Condition is good as shown in photos.</strong></span></li>
<li><span style="color: #000000;"><strong>Price indicated is for each.</strong></span></li>
<li><span style="color: #000000;"><strong>Immediately available for dispatch, and this product is offered with a 3 month warranty period.</strong></span></li>
</ul>
</div>
</div>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/ingmar-medical-adult-pediatric-demonstration-lung-model/">IngMar Medical Adult/Pediatric Demonstration Lung Model</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MASAR PMA-1 Pacemaker Analyzer</title>
		<link>https://robinmedical.co.uk/product/masar-pma-1-pacemaker-analyzer/</link>
		
		<dc:creator><![CDATA[r@bnm32_admin]]></dc:creator>
		<pubDate>Thu, 04 Sep 2025 10:32:01 +0000</pubDate>
				<guid isPermaLink="false">https://robinmedical.co.uk/?post_type=product&#038;p=17019</guid>

					<description><![CDATA[<p>The MASAR PMA-1 Pacemaker Analyzer is a compact, portable device designed for the comprehensive testing and analysis of cardiac pacemakers. It is a vital tool for biomedical technicians and cardiologists,</p>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/masar-pma-1-pacemaker-analyzer/">MASAR PMA-1 Pacemaker Analyzer</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="color: #000000;">The <span style="color: #0000ff;"><strong>MASAR PMA-1 Pacemaker Analyzer</strong></span> is a compact, portable device designed for the comprehensive testing and analysis of cardiac pacemakers. It is a vital tool for biomedical technicians and cardiologists, allowing for the verification of both temporary and permanent pacemaker functions. <span class="citation-3 citation-end-3">The PMA-1 can measure and evaluate key parameters such as pulse amplitude, pulse width, and rate, ensuring the pacemaker is operating correctly and safely.</span> Its intuitive design and high accuracy make it a reliable device for performance validation and troubleshooting.</span></p>
<hr data-start="782" data-end="785" />
<h2 data-start="787" data-end="814"><span style="color: #000000;">Technical Specifications:</span></h2>
<div class="_tableContainer_1rjym_1">
<div class="_tableContainer_1rjym_1">
<div class="group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="731" data-end="2125">
<thead data-start="731" data-end="845">
<tr data-start="731" data-end="845">
<th data-start="731" data-end="760" data-col-size="sm"><span style="color: #000000;"><strong data-start="733" data-end="746">Feature / Parameter</strong></span></th>
<th data-start="760" data-end="845" data-col-size="md"><span style="color: #000000;"><strong data-start="762" data-end="779">Specification</strong></span></th>
</tr>
</thead>
<tbody data-start="961" data-end="2125">
<tr data-start="961" data-end="1074">
<td data-start="961" data-end="990" data-col-size="sm"><span style="color: #000000;"><strong data-start="963" data-end="979">Manufacturer</strong></span></td>
<td data-start="990" data-end="1074" data-col-size="md"><span style="color: #000000;">Bio-Tek Instruments, Inc. (now part of Fluke Biomedical)</span></td>
</tr>
<tr data-start="1075" data-end="1189">
<td data-start="1075" data-end="1104" data-col-size="sm"><span style="color: #000000;"><strong data-start="1077" data-end="1100">Model / Part Number</strong></span></td>
<td data-start="1104" data-end="1189" data-col-size="md"><span style="color: #000000;">PMA-1 / DALE 400</span></td>
</tr>
<tr data-start="1190" data-end="1304">
<td data-start="1190" data-end="1219" data-col-size="sm"><span style="color: #000000;"><strong data-start="1192" data-end="1203">Display</strong></span></td>
<td data-start="1219" data-end="1304" data-col-size="md"><span style="color: #000000;">2-line × 16-character LCD</span></td>
</tr>
<tr data-start="1305" data-end="1419">
<td data-start="1305" data-end="1334" data-col-size="sm"><span style="color: #000000;"><strong data-start="1307" data-end="1317">Inputs</strong></span></td>
<td data-start="1334" data-end="1419" data-col-size="md"><span style="color: #000000;">&#8211; Ventricle pacing signal: 0–12 V, 25 mA, 500 Ω load</span></td>
</tr>
<tr data-start="1420" data-end="1534">
<td data-start="1420" data-end="1449" data-col-size="sm"></td>
<td data-start="1449" data-end="1534" data-col-size="md"><span style="color: #000000;">&#8211; Atrial pacing signal: 0–12 V, 25 mA, 500 Ω load</span></td>
</tr>
<tr data-start="1535" data-end="1649">
<td data-start="1535" data-end="1564" data-col-size="sm"></td>
<td data-start="1564" data-end="1649" data-col-size="md"><span style="color: #000000;">&#8211; Transthoracic pacing signal: 0–40 V, 250 mA, 50 Ω load</span></td>
</tr>
<tr data-start="1650" data-end="1764">
<td data-start="1650" data-end="1679" data-col-size="sm"><span style="color: #000000;"><strong data-start="1652" data-end="1663">Outputs</strong></span></td>
<td data-start="1679" data-end="1764" data-col-size="md"><span style="color: #000000;">&#8211; Parallel printer port</span></td>
</tr>
<tr data-start="1765" data-end="1879">
<td data-start="1765" data-end="1794" data-col-size="sm"></td>
<td data-start="1794" data-end="1879" data-col-size="md"><span style="color: #000000;">&#8211; Serial computer port</span></td>
</tr>
<tr data-start="1880" data-end="2008">
<td data-start="1880" data-end="1909" data-col-size="sm"><span style="color: #000000;"><strong data-start="1882" data-end="1896">Test Modes</strong></span></td>
<td data-start="1909" data-end="2008" data-col-size="md"><span style="color: #000000;">&#8211; Otis Mode: Operate all tests from a computer, with print-strip details copied to the computer</span></td>
</tr>
<tr data-start="2009" data-end="2125">
<td data-start="2009" data-end="2038" data-col-size="sm"></td>
<td data-start="2038" data-end="2125" data-col-size="md"><span style="color: #000000;">&#8211; Interactive Mode: Full control, including some automatic testing, from a computer</span></td>
</tr>
</tbody>
</table>
<p><span style="color: #000000;"><strong>1X Used unit in stock.<br />
</strong><strong>Immediately available for dispatch, patient ready and this product is offered with a 3 month warranty period.</strong></span></p>
</div>
</div>
</div>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/masar-pma-1-pacemaker-analyzer/">MASAR PMA-1 Pacemaker Analyzer</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Covidien Genius™ 2 Thermometer Checker / Calibrator</title>
		<link>https://robinmedical.co.uk/product/covidien-genius-2-thermometer-checker-calibrator/</link>
		
		<dc:creator><![CDATA[r@bnm32_admin]]></dc:creator>
		<pubDate>Mon, 03 Mar 2025 16:57:20 +0000</pubDate>
				<guid isPermaLink="false">https://robinmedical.co.uk/?post_type=product&#038;p=15659</guid>

					<description><![CDATA[<p>The Covidien Genius™ 2 Thermometer Checker / Calibrator is a precision instrument designed to verify the accuracy and performance of the Genius™ 3 and Genius™ 2 Tympanic Thermometer. This compact</p>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/covidien-genius-2-thermometer-checker-calibrator/">Covidien Genius™ 2 Thermometer Checker / Calibrator</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p class="" data-start="238" data-end="761"><span style="color: #000000;"><strong>The <span style="color: #0000ff;">Covidien Genius<img src="https://s.w.org/images/core/emoji/16.0.1/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> 2 Thermometer Checker / Calibrator</span> is a precision instrument designed to verify the accuracy and performance of the Genius<img src="https://s.w.org/images/core/emoji/16.0.1/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> 3 and Genius<img src="https://s.w.org/images/core/emoji/16.0.1/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> 2 Tympanic Thermometer. This compact and reliable checker ensures that thermometers are functioning within defined clinical standards, helping healthcare providers maintain accurate temperature readings in patient care environments. Easy to operate and portable, the Genius<img src="https://s.w.org/images/core/emoji/16.0.1/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> 2 checker is an essential tool for clinical quality assurance and routine equipment validation.</strong></span></p>
<hr class="" data-start="763" data-end="766" />
<h3 class="" data-start="768" data-end="800"><span style="color: #0000ff;"><strong data-start="772" data-end="800">Technical Specifications:</strong></span></h3>
<div class="pointer-events-none relative left-[50%]! flex w-[100cqw] translate-x-[-50%] justify-center *:pointer-events-auto">
<div class="tableContainer horzScrollShadows group relative">
<table class="min-w-full" data-start="802" data-end="2330">
<thead data-start="802" data-end="904">
<tr data-start="802" data-end="904">
<th data-start="802" data-end="838"><span style="color: #000000;"><strong data-start="804" data-end="821">Specification</strong></span></th>
<th data-start="838" data-end="904"><span style="color: #000000;"><strong data-start="840" data-end="851">Details</strong></span></th>
</tr>
</thead>
<tbody data-start="1007" data-end="2330">
<tr data-start="1007" data-end="1108">
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="1007" data-end="1042"><span style="color: #000000;"><strong data-start="1009" data-end="1025">Product Name</strong></span></td>
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)] min-w-[calc(var(--thread-content-max-width)/3)]" data-start="1042" data-end="1108"><span style="color: #000000;"><strong>Genius 2 Thermometer Checker / Calibrator</strong></span></td>
</tr>
<tr data-start="1109" data-end="1210">
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="1109" data-end="1144"><span style="color: #000000;"><strong data-start="1111" data-end="1133">Compatible Devices</strong></span></td>
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="1144" data-end="1210"><span style="color: #000000;"><strong>Covidien Genius 2 and Genius 3 Tympanic Thermometer</strong></span></td>
</tr>
<tr data-start="1211" data-end="1312">
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="1211" data-end="1246"><span style="color: #000000;"><strong data-start="1213" data-end="1245">Temperature Simulation Range</strong></span></td>
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)] min-w-[calc(var(--thread-content-max-width)/3)]" data-start="1246" data-end="1312"><span style="color: #000000;"><strong>Approx. 37.0°C (98.6°F) ± allowable margin</strong></span></td>
</tr>
<tr data-start="1313" data-end="1414">
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="1313" data-end="1348"><span style="color: #000000;"><strong data-start="1315" data-end="1331">Power Source</strong></span></td>
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)] min-w-[calc(var(--thread-content-max-width)/3)]" data-start="1348" data-end="1414"><span style="color: #000000;"><strong>Battery-operated (typically AA or included battery pack)</strong></span></td>
</tr>
<tr data-start="1415" data-end="1516">
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="1415" data-end="1450"><span style="color: #000000;"><strong data-start="1417" data-end="1435">User Interface</strong></span></td>
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="1450" data-end="1516"><span style="color: #000000;"><strong>Single-button operation</strong></span></td>
</tr>
<tr data-start="1517" data-end="1617">
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="1517" data-end="1551"><span style="color: #000000;"><strong data-start="1519" data-end="1540">Verification Time</strong></span></td>
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="1551" data-end="1617"><span style="color: #000000;"><strong>Less than 5 seconds</strong></span></td>
</tr>
<tr data-start="1618" data-end="1719">
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="1618" data-end="1653"><span style="color: #000000;"><strong data-start="1620" data-end="1635">Portability</strong></span></td>
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="1653" data-end="1719"><span style="color: #000000;"><strong>Compact, handheld size</strong></span></td>
</tr>
<tr data-start="1720" data-end="1821">
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="1720" data-end="1755"><span style="color: #000000;"><strong data-start="1722" data-end="1735">Indicator</strong></span></td>
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="1755" data-end="1821"><span style="color: #000000;"><strong>LED status light (pass/fail indication)</strong></span></td>
</tr>
<tr data-start="1822" data-end="1922">
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="1822" data-end="1856"><span style="color: #000000;"><strong data-start="1824" data-end="1849">Accuracy Check Method</strong></span></td>
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="1856" data-end="1922"><span style="color: #000000;"><strong>Infrared detection and reference source</strong></span></td>
</tr>
<tr data-start="1923" data-end="2024">
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="1923" data-end="1958"><span style="color: #000000;"><strong data-start="1925" data-end="1941">Construction</strong></span></td>
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)] min-w-[calc(var(--thread-content-max-width)/3)]" data-start="1958" data-end="2024"><span style="color: #000000;"><strong>Durable, impact-resistant plastic housing</strong></span></td>
</tr>
<tr data-start="2025" data-end="2126">
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="2025" data-end="2060"><span style="color: #000000;"><strong data-start="2027" data-end="2045">Certifications</strong></span></td>
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)] min-w-[calc(var(--thread-content-max-width)/3)]" data-start="2060" data-end="2126"><span style="color: #000000;"><strong>Factory-calibrated, CE marked, RoHS compliant</strong></span></td>
</tr>
<tr data-start="2127" data-end="2228">
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="2127" data-end="2162"><span style="color: #000000;"><strong data-start="2129" data-end="2143">Dimensions</strong></span></td>
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="2162" data-end="2228"><span style="color: #000000;"><strong>Approx. 10 × 6 × 4 cm</strong></span></td>
</tr>
<tr data-start="2229" data-end="2330">
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="2229" data-end="2264"><span style="color: #000000;"><strong data-start="2231" data-end="2241">Weight</strong></span></td>
<td class="max-w-[calc(var(--thread-content-max-width)*2/3)]" data-start="2264" data-end="2330"><span style="color: #000000;"><strong>Approx. 200 g</strong></span></td>
</tr>
</tbody>
</table>
</div>
</div>
<hr class="" data-start="2332" data-end="2335" />
<h3 class="" data-start="2337" data-end="2357"><span style="color: #0000ff;"><strong data-start="2341" data-end="2357">Key Features:</strong></span></h3>
<ul data-start="2359" data-end="3326">
<li class="" data-start="2359" data-end="2481">
<p class="" data-start="2361" data-end="2481"><span style="color: #000000;"><strong>Ensures Accurate Temperature Readings: Verifies that Genius 3 &amp; 2 thermometers remain calibrated to clinical standards.</strong></span></p>
</li>
<li class="" data-start="2482" data-end="2617">
<p class="" data-start="2484" data-end="2617"><span style="color: #000000;"><strong>Quick and Simple Operation: Just insert the thermometer probe and press the button—results are provided instantly via status LED.</strong></span></p>
</li>
<li class="" data-start="2618" data-end="2721">
<p class="" data-start="2620" data-end="2721"><span style="color: #000000;"><strong>Compact and Portable Design: Lightweight and easy to transport between departments or facilities.</strong></span></p>
</li>
<li class="" data-start="2722" data-end="2865">
<p class="" data-start="2724" data-end="2865"><span style="color: #000000;"><strong>Reliable Quality Control Tool: Ideal for hospitals, clinics, and healthcare facilities aiming to maintain consistent diagnostic accuracy.</strong></span></p>
</li>
<li class="" data-start="2866" data-end="2998">
<p class="" data-start="2868" data-end="2998"><span style="color: #000000;"><strong>Battery-Powered Convenience: Operates without the need for external power sources—great for mobile medical teams or field use.</strong></span></p>
</li>
<li class="" data-start="2999" data-end="3101">
<p class="" data-start="3001" data-end="3101"><span style="color: #000000;"><strong>Durable Medical Build: Designed to withstand repeated use in fast-paced healthcare environments.</strong></span></p>
</li>
<li class="" data-start="3102" data-end="3215">
<p class="" data-start="3104" data-end="3215"><span style="color: #000000;"><strong>Factory-Calibrated: Comes ready to use with no need for user calibration, minimizing downtime and training.</strong></span></p>
</li>
<li class="" data-start="3216" data-end="3326">
<p class="" data-start="3218" data-end="3326"><span style="color: #000000;"><strong>Supports Infection Control: Allows validation of thermometer performance without direct patient contact.</strong></span></p>
</li>
</ul>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/covidien-genius-2-thermometer-checker-calibrator/">Covidien Genius™ 2 Thermometer Checker / Calibrator</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Pacer analyzer PMA-1</title>
		<link>https://robinmedical.co.uk/product/pacer-analyzer-pma-1/</link>
		
		<dc:creator><![CDATA[r@bnm32_admin]]></dc:creator>
		<pubDate>Sat, 03 Feb 2024 14:25:55 +0000</pubDate>
				<guid isPermaLink="false">https://robinmedical.co.uk/?post_type=product&#038;p=14733</guid>

					<description><![CDATA[<p>Bio-tek PMA-1 (DALE 400) External Pacer analyzer , in good physical and operational condition, its actual photo displayed. Can be offered with fresh calibration certificate. Supplied With: Test leads &#38;</p>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/pacer-analyzer-pma-1/">Pacer analyzer PMA-1</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="color: #000000;"><strong><span style="color: #0000ff;">Bio-tek PMA-1 (DALE 400) External Pacer analyzer </span></strong></span>, <span style="color: #000000;"><strong>in good physical and operational condition, its actual photo displayed.</strong></span></p>
<ul>
<li><span style="color: #000000;"><strong>Can be offered with fresh calibration certificate.</strong></span></li>
<li><span style="color: #000000;"><strong>S</strong><strong><span style="color: #000000;">upplied</span> With: Test leads &amp; Operating manual.</strong></span></li>
<li><span style="color: #000000;"><strong>Immediate dispatch </strong></span></li>
<li></li>
<li><span style="color: #0000ff;"><strong>Features:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Eternal Pacemaker Analyzer Testing for an entire range of external pacemakers.</strong></span></li>
<li><span style="color: #000000;"><b style="color: #000000;">DALE400 has been specifically designed for use with all external cardiac pacemakers including invasive (transvenous) and </b><span style="color: #000000;"><b>non-invasive</b></span><b style="color: #000000;"> (transcutaneous) types. Its impressive range of tests and simulations will meet </b></span><span style="color: #000000;"><strong>the needs of all cardiac units.</strong></span></li>
<li><span style="color: #000000;"><strong>Handheld portability</strong></span></li>
<li><span style="color: #000000;"><strong>All necessary test leads</strong></span></li>
<li><span style="color: #000000;"><strong>Large, 2-line LCD display</strong></span></li>
<li><span style="color: #000000;"><strong>Comprehensive test ranges</strong></span></li>
<li><span style="color: #000000;"><strong>Replaces 5 separate test devices</strong></span></li>
</ul>
</li>
<li></li>
<li><span style="color: #0000ff;"> <strong>Specifications:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Display:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>2-line × 16-character LCD</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Inputs</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Ventricle pacing signal: (0-12 V, 25 mA), (500 Ω load)</strong></span></li>
<li><span style="color: #000000;"><strong>Atrial pacing signal: (0-12 V, 25 mA), (500 Ω load)</strong></span></li>
<li><span style="color: #000000;"><strong>Transthoracic pacing signal: (0-40 V, 250 mA), (50 Ω load)</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Outputs:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Parallel printer port</strong></span></li>
<li><span style="color: #000000;"><strong>Serial computer port</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Measurement of Pacing Pulse</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Amplitude: 0 to12 V invasive, 0 to 40 V noninvasive</strong></span></li>
<li><span style="color: #000000;"><strong>Rate: 30 to 300 BPM</strong></span></li>
<li><span style="color: #000000;"><strong>Pulse length: (&lt; 1 to 50 ms)</strong></span></li>
<li><span style="color: #000000;"><strong>AV Time Interval: 0 to 1000 ms</strong></span></li>
<li><span style="color: #000000;"><strong>50/60 Hz Interference Signal: 0 to 25 mV in 1 mV steps</strong></span></li>
<li><span style="color: #000000;"><strong>Refractory Period Measurement: 20 to 500 ms</strong></span></li>
<li><span style="color: #000000;"><strong>Simulated R-, S- &amp; T-Waves: Width 5, 10…, 100, 200 ms</strong></span></li>
<li><span style="color: #000000;"><strong>Waveforms: Square, triangle, haversine, ISO Rate (30 to 120 BPM)</strong></span></li>
<li><span style="color: #000000;"><strong>Amplitude: 0 to 25 mV, in 0.5 mV steps</strong></span></li>
<li><span style="color: #000000;"><strong>Long-Term Tests: Reference value for pulse rate, amplitude and length established from first 10 pulses. Thereafter, any deviation over 10% (adjustable) is flagged.</strong></span></li>
<li><span style="color: #000000;"><strong>Power: Four AA cells, Current drawn 20 mA approx. or connect to 9 VDC supply.</strong></span></li>
<li><span style="color: #000000;"><strong>Dimensions: 7.5” L × 5.5” W × 1.5” H (18 cm L × 13 cm W × 4 cm H)</strong></span></li>
<li><span style="color: #000000;"><strong>Weight: 1.54 lbs (700 g)</strong></span></li>
</ul>
</li>
</ul>
</li>
</ul>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/pacer-analyzer-pma-1/">Pacer analyzer PMA-1</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Metron QA-45 Defibrillator/Pacer Tester</title>
		<link>https://robinmedical.co.uk/product/metron-qa-45-defibrillator-pacer-tester/</link>
		
		<dc:creator><![CDATA[r@bnm32_admin]]></dc:creator>
		<pubDate>Thu, 18 Jan 2024 19:36:19 +0000</pubDate>
				<guid isPermaLink="false">https://robinmedical.co.uk/?post_type=product&#038;p=14721</guid>

					<description><![CDATA[<p><span style="color: #ff0000;"><strong>SOLD OUT</strong></span></p>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/metron-qa-45-defibrillator-pacer-tester/">Metron QA-45 Defibrillator/Pacer Tester</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="color: #000000;"><span style="color: #0000ff;"><span style="color: #0000ff;"><b>Metron QA-45 Defibrillator and Transcutaneous Pacer </b></span><span style="color: #0000ff;"><b>Analyser</b></span><span style="color: #0000ff;"><b> &amp; Simulator</b></span></span><b style="color: #000000;">, in very good physical and operational condition, analyzer&#8217;s actual photos displayed.</b></span></p>
<ul>
<li><span style="color: #000000;"><strong>Code: 13020</strong></span></li>
<li><span style="color: #000000;"><strong>Version: 2.6</strong></span></li>
<li></li>
<li><span style="color: #000000;"><strong>Offered with 3 months warranty.</strong></span></li>
<li><span style="color: #000000;"><strong>Immediate Dispatch.</strong></span></li>
<li></li>
<li><span style="color: #000000;"><strong>Can be offered with Fresh calibration Certificate at extra cost</strong></span></li>
<li></li>
<li><span style="color: #0000ff;"><strong>Features:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Energy and cardioversion measurement.</strong></span></li>
<li><span style="color: #000000;"><strong>Peak voltage and current reading.</strong></span></li>
<li><span style="color: #000000;"><strong>Storage and playback of output waveform.</strong></span></li>
<li><span style="color: #000000;"><strong>12 lead ECG simulation.</strong></span></li>
<li><span style="color: #000000;"><strong>ECG, Performance and Arrhythmia simulation.</strong></span></li>
<li><span style="color: #000000;"><strong>Automatic defibrillator test procedures. (Emergency scenarios using PRO-Soft QA-40M/45)</strong></span></li>
<li><span style="color: #000000;"><strong>Pacemaker loads from 50 ohm to 2300 ohm.</strong></span></li>
<li><span style="color: #000000;"><strong>Accuracy Tests: Amplitude, Rate, Pulse Width.</strong></span></li>
<li><span style="color: #000000;"><strong>Demand Sensitivity Tests.</strong></span></li>
<li><span style="color: #000000;"><strong>Refractory Period Tests: Sensed and Paced.</strong></span></li>
<li><span style="color: #000000;"><strong>60/50 Hz Immunity Test.</strong></span></li>
<li><span style="color: #000000;"><strong>Pulse Energy.</strong></span></li>
<li><span style="color: #000000;"><strong>Large graphic display.</strong></span></li>
<li><span style="color: #000000;"><strong>RS-232C and Centronic printer interface.</strong></span></li>
<li><span style="color: #000000;"><strong>Battery operation or AC adapter.</strong></span></li>
<li><span style="color: #000000;"><strong>The QA-45 Defibrillator / Transcutaneous Pacemaker Analyzer is a precision instrument for testing defibrillators and external (transcutaneous) pacemakers. The built-in test procedures and extensive resistance loads for pacer testing, make the QA-45 a versatile test instrument and solid value.</strong></span></li>
<li><span style="color: #000000;"><strong>The test results can either be written directly to a printer from the QA-45, or they may be transferred to PRO-Soft QA-40M/45 test automation software. With PRO-Soft, you can make your own test protocols, store protocols and test results to disk, and provide test data to update your equipment management database</strong></span></li>
</ul>
</li>
<li></li>
<li><strong><span style="color: #0000ff;">Specifications:</span></strong>
<ul>
<li><span style="color: #000000;"><strong>DEFIBRILLATOR ANALYZER:</strong></span>
<ul>
<li><span style="color: #000000;"><strong> Energy Output Measurement: </strong></span>
<ul>
<li><span style="color: #000000;"><strong>High Range: </strong></span>
<ul>
<li><span style="color: #000000;"><strong>Voltage: &lt;5000 V </strong></span></li>
<li><span style="color: #000000;"><strong>Maximum Energy: 1000 J </strong></span></li>
<li><span style="color: #000000;"><strong>Accuracy: ±2 % of reading for &gt; 100 J ±2 J of reading for &lt; 100 J </strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Low Range: </strong></span>
<ul>
<li><span style="color: #000000;"><strong>Voltage: &lt; 1000 V </strong></span></li>
<li><span style="color: #000000;"><strong>Maximum Energy: 50 J </strong></span></li>
<li><span style="color: #000000;"><strong>Accuracy: ±2 % of reading for &gt; 20 J ±2 J of reading for &lt; 20 J </strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Load Resistance: 50 ohms ±1 %; non-inductive (&lt; 1 µH) </strong></span></li>
<li><span style="color: #000000;"><strong>Display Resolution: 0.1 J </strong></span></li>
<li><span style="color: #000000;"><strong>Measurement Time Window: 100 ms </strong></span></li>
<li><span style="color: #000000;"><strong>Absolute Max Peak Voltage: 6000 V </strong></span></li>
<li><span style="color: #000000;"><strong>Absolute Max Peak Current: 120 A Pulse Width: 100 ms </strong></span></li>
<li><span style="color: #000000;"><strong>Oscilloscope Output: </strong></span>
<ul>
<li><span style="color: #000000;"><strong>High Range: 1000:1 amplitude attenuation </strong></span></li>
<li><span style="color: #000000;"><strong>Low Range: 200:1 amplitude attenuation </strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Waveform Storage / Playback: Discharge can be viewed via ECG outputs and paddles. </strong></span></li>
<li><span style="color: #000000;"><strong>Output: 200:1 Time Base Expansion </strong></span></li>
<li><span style="color: #000000;"><strong>Sync Time Measurements: </strong></span>
<ul>
<li><span style="color: #000000;"><strong>Timing Window: Starts &#8211; 40 ms at each R wave peak </strong></span></li>
<li><span style="color: #000000;"><strong>Test Waveforms: All Waveform simulations available. </strong></span></li>
<li><span style="color: #000000;"><strong>Delay Time Accuracy: ±1 ms </strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Charge Time Measurement: 0.1 to 99.9 seconds</strong></span></li>
</ul>
</li>
</ul>
</li>
<li><span style="color: #000000;"><strong>ECG WAVEFORM SIMULATIONS:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>ECG General:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Lead Configuration: 12-lead simulation. RL, RA, LA, LL, V1-6</strong></span></li>
<li><span style="color: #000000;"><strong>Output Impedance: </strong></span>
<ul>
<li><span style="color: #000000;"><strong>Limb leads: 1000 ohms to RL</strong></span></li>
<li><span style="color: #000000;"><strong>V Leads: 1000 ohms to RL</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>High Level Output: 1.0 V/mV of low level (lead II)</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Manual ECG Performance Test:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Square wave: 2 Hz 1.0 mV p-p bipolar</strong></span></li>
<li><span style="color: #000000;"><strong>DC Pulse: 4.0 seconds 1.0 mV</strong></span></li>
<li><span style="color: #000000;"><strong>Sine waves: 0.1, 0.2, 0.5, 10, 40, 50, 60, 100 Hz</strong></span></li>
<li><span style="color: #000000;"><strong>Triangle wave: 2.0 Hz</strong></span></li>
<li><span style="color: #000000;"><strong>Amplitudes: 0.5, 1.0, 1.5, 2.0 mV (Lead II)</strong></span></li>
<li><span style="color: #000000;"><strong>Amplitude accuracy : ±5 % (Lead II 1.0 mV)</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>ECG Performance Test:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Gain/Damping: 2 Hz square wave</strong></span></li>
<li><span style="color: #000000;"><strong>Frequency Response: Low Frequency: 4 second DC pulse</strong></span></li>
<li><span style="color: #000000;"><strong>Band Pass: 10 Hz sine</strong></span></li>
<li><span style="color: #000000;"><strong>Monitor: -3dB point: 40 Hz sine</strong></span></li>
<li><span style="color: #000000;"><strong>Power Line Notch Filter: 50 Hz sine</strong></span></li>
<li><span style="color: #000000;"><strong>Linearity: 2 Hz triangle wave</strong></span></li>
<li><span style="color: #000000;"><strong>Normal Sinus: Rates: 30, 60, 80, 120, 180, 240 &amp; 300 BPM</strong></span></li>
<li><span style="color: #000000;"><strong>Rate accuracy: ±1 % of selection</strong></span></li>
<li><span style="color: #000000;"><strong>Amplitudes: 0.5, 1.0, 1.5, 2.0 mV (Lead II)</strong></span></li>
<li><span style="color: #000000;"><strong>Amplitude accuracy: ±5 % (Lead II 1.0 mV)</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>AUTOMATIC ECG RATE TEST:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Arrhythmia Selections: </strong></span>
<ul>
<li><span style="color: #000000;"><strong>Atrial Fibrillation 1 &amp; 2</strong></span></li>
<li><span style="color: #000000;"><strong>Premature Atrial Contraction</strong></span></li>
<li><span style="color: #000000;"><strong>PVC</strong></span></li>
<li><span style="color: #000000;"><strong>Early PVC</strong></span></li>
<li><span style="color: #000000;"><strong>R on T PVC</strong></span></li>
<li><span style="color: #000000;"><strong>Multifocal PVCs</strong></span></li>
<li><span style="color: #000000;"><strong>Bigeminy</strong></span></li>
<li><span style="color: #000000;"><strong>Bigeminy Run of 5 PVCs</strong></span></li>
<li><span style="color: #000000;"><strong>Ventricular Tachycardia</strong></span></li>
<li><span style="color: #000000;"><strong>Ventricular Fibrillation</strong></span></li>
<li><span style="color: #000000;"><strong>Second Degree Type 2</strong></span></li>
<li><span style="color: #000000;"><strong>Right Bundle Branch Block</strong></span></li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><span style="color: #000000;"><strong>TRANS. PACEMAKER ANALYZER:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Test Load Range:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>50 to 2300 ohms in step of:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>– 50 ohm up to 200 ohms</strong></span></li>
<li><span style="color: #000000;"><strong>– 100ohm from 200 up to 2300 ohms</strong></span></li>
</ul>
</li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Accuracy:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>50 &#8211; 1300 ohm ±1 %</strong></span></li>
<li><span style="color: #000000;"><strong>1400 &#8211; 2300 ohm ±1.5 %</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Oscilloscope Output:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>50 &#8211; 150 ohm10.24:1amplitude attenuation</strong></span></li>
<li><span style="color: #000000;"><strong>200 &#8211; 500 ohm41:1 amplitude attenuation</strong></span></li>
<li><span style="color: #000000;"><strong>600 &#8211; 2300 ohm164:1 amplitude attenuation</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Pulse Measurements:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Amplitude: 4 to 300 mA (100 ohm load)</strong></span></li>
<li><span style="color: #000000;"><strong>Accuracy: ±5 % or ±0.5 mA</strong></span></li>
<li><span style="color: #000000;"><strong>Max. amplitude: 300 mA all loads</strong></span></li>
<li><span style="color: #000000;"><strong>Rate: 30 to 800 ppm</strong></span></li>
<li><span style="color: #000000;"><strong>Accuracy: ±1 % or 2 ppm</strong></span></li>
<li><span style="color: #000000;"><strong>Pulse Width: 0.6 to 80 ms</strong></span></li>
<li><span style="color: #000000;"><strong>Accuracy: ±1 % or ±0.3 ms</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Demand Sensitivity Test:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Waveforms: Square(SQR), Triangle(TRI), and Haversine (SSQ)</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>ECG Output:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Amplitude: 0 &#8211; 4 mV</strong></span></li>
<li><span style="color: #000000;"><strong>Resolution: 40 µV</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Pacer Input (Load dependent):</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Amplitude (50 ohm): 0 &#8211; 10 mV</strong></span></li>
<li><span style="color: #000000;"><strong>Resolution (50 ohm): 40 µV</strong></span></li>
<li><span style="color: #000000;"><strong>Amplitude: (³500 ohm): 0 &#8211; 100 mV</strong></span></li>
<li><span style="color: #000000;"><strong>Resolution: (³500 ohm): 1 mV</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Defib. Pads:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Amplitude: 0 &#8211; 10 mV</strong></span></li>
<li><span style="color: #000000;"><strong>Resolution: 0.1 mV</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Waveform width: 10, 25, 40, 100 and 200 ms</strong></span></li>
<li><span style="color: #000000;"><strong>Pacer rate: 30 to 120 ppm</strong></span></li>
<li><span style="color: #000000;"><strong>Immunity Test: 50/60 Hz Interference Signal</strong></span></li>
<li><span style="color: #000000;"><strong>ECG Output: 0 &#8211; 4 mV peak in step of 0.4 mV</strong></span></li>
<li><span style="color: #000000;"><strong>Pacer Input (Load dependent):</strong></span>
<ul>
<li><span style="color: #000000;"><strong>0 &#8211; 10 mV peak in step of 1 mV (50 ohm)</strong></span></li>
<li><span style="color: #000000;"><strong>0 &#8211; 100 mV peak in step of 10 mV (³500 ohm)</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Defib. Pads: 0 &#8211; 10 mV peak in step of 1 mV</strong></span></li>
<li><span style="color: #000000;"><strong>Refractory Period Measurement:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>20 to 500 ms (both Pacing and Sensing)</strong></span></li>
<li><span style="color: #000000;"><strong>Accuracy: ±2 ms</strong></span></li>
</ul>
</li>
</ul>
</li>
<li><span style="color: #000000;"><strong>GENERAL INFORMATION</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Temperature Range:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>+15°C to +35°C when operating.</strong></span></li>
<li><span style="color: #000000;"><strong>0°C to +50°C in storage.</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Display:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Type: LCD graphic display.</strong></span></li>
<li><span style="color: #000000;"><strong>Alphanumeric format: 8 lines by 40 characters.</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Data Input/Outputs (2):</strong></span>
<ul>
<li><span style="color: #000000;"><strong>Parallel printerport (1); Bi-Directional</strong></span></li>
<li><span style="color: #000000;"><strong>RS-232C (1) for Computer control.</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Power:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>2 x 9 Volt Alkaline Battery.</strong></span></li>
<li><span style="color: #000000;"><strong>240 VAC Battery Eliminator.</strong></span></li>
<li><span style="color: #000000;"><strong>115 VAC Battery EL. For US.</strong></span></li>
</ul>
</li>
<li><span style="color: #000000;"><strong>Housing: High impact plastic case.</strong></span></li>
<li><span style="color: #000000;"><strong>DIMENSIONS: D x W x H: 28.0 cm x 24.8 cm x 9.8 cm. 11 in x 9.8 in x 3.9 in.</strong></span></li>
<li><span style="color: #000000;"><strong>Weight: 1.85 kg / 4.1 lbs. with battery.</strong></span></li>
<li><span style="color: #000000;"><strong>Recommended Printers: HP Deskjet, Canon Bubble Jet, or compatible</strong></span></li>
</ul>
</li>
</ul>
</li>
</ul>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/metron-qa-45-defibrillator-pacer-tester/">Metron QA-45 Defibrillator/Pacer Tester</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Bio-Tek QED-6M Defibrillator Tester</title>
		<link>https://robinmedical.co.uk/product/bio-tek-qed-6-defibrillator-tester/</link>
		
		<dc:creator><![CDATA[r@bnm32_admin]]></dc:creator>
		<pubDate>Tue, 04 Apr 2023 16:37:30 +0000</pubDate>
				<guid isPermaLink="false">https://robinmedical.co.uk/?post_type=product&#038;p=14179</guid>

					<description><![CDATA[<p><span style="color: #ff0000;"><strong>SOLD OUT</strong></span></p>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/bio-tek-qed-6-defibrillator-tester/">Bio-Tek QED-6M Defibrillator Tester</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="color: #000000;"><strong><span style="color: #0000ff;">Bio-Tek QED-6M Defibrillator Tester</span>, in very good physical and operational condition, tester&#8217;s actual photos displayed.</strong></span></p>
<ul>
<li><span style="color: #000000;"><strong>Offered with 3 months warranty.</strong></span></li>
<li><span style="color: #000000;"><strong>Supplied with:</strong></span>
<ul>
<li><span style="color: #000000;"><strong> 2 adapters </strong></span></li>
<li><span style="color: #000000;"><strong>Operating manual.</strong></span></li>
</ul>
</li>
<li></li>
<li><span style="color: #000000;"><strong>Immediate Dispatch.</strong></span></li>
<li><span style="color: #000000;"><strong>Can be offered with Fresh calibration Certificate at extra cost</strong></span></li>
<li></li>
<li><span style="color: #000000;"><strong>Features:</strong></span>
<ul>
<li><span style="color: #000000;"><strong> output energy, sync time, peak measurements, overshoot, bi-directional RS232, waveforms, charge time measurements, 28 programmable autosequences, </strong></span></li>
<li><span style="color: #000000;"><strong>Run on 9VDC PP3 battery or mains power adapter.</strong></span></li>
<li></li>
<li><span style="color: #000000;"><strong>Note: pacer option<span style="color: #000000;"> is not </span>installed.</strong></span></li>
</ul>
</li>
</ul>
<p>&nbsp;</p>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/bio-tek-qed-6-defibrillator-tester/">Bio-Tek QED-6M Defibrillator Tester</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Verathon Calibration Tank</title>
		<link>https://robinmedical.co.uk/product/verathon-calibration-tank/</link>
		
		<dc:creator><![CDATA[r@bnm32_admin]]></dc:creator>
		<pubDate>Sun, 01 Jan 2023 16:44:34 +0000</pubDate>
				<guid isPermaLink="false">https://robinmedical.co.uk/?post_type=product&#038;p=13704</guid>

					<description><![CDATA[<p><span style="color: #ff0000;"><strong>SOLD OUT</strong></span></p>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/verathon-calibration-tank/">Verathon Calibration Tank</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="color: #000000;"><strong><span style="color: #0000ff;">Verathon Calibration Tank</span>, in very good physical condition, tank&#8217;s actual photos displayed.</strong></span></p>
<ul>
<li><span style="color: #000000;"><strong>P/N: 0620-0340</strong></span></li>
<li><span style="color: #000000;"><strong>For calibrating US probe for BladerScan BVI 6000 &amp; 9000 Series balder scanners.</strong></span></li>
<li><span style="color: #000000;"><strong>3 parts system: Tank Base, calibration target &amp; Tank Lid</strong></span></li>
<li></li>
<li><span style="color: #000000;"><strong>Immediate dispatch.</strong></span></li>
</ul>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/verathon-calibration-tank/">Verathon Calibration Tank</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Viamed VG900 SPO2 Sensors Test Unit</title>
		<link>https://robinmedical.co.uk/product/viamed-vg900-spo2-sensors-test-unit/</link>
		
		<dc:creator><![CDATA[r@bnm32_admin]]></dc:creator>
		<pubDate>Tue, 13 Dec 2022 18:51:00 +0000</pubDate>
				<guid isPermaLink="false">https://robinmedical.co.uk/?post_type=product&#038;p=13557</guid>

					<description><![CDATA[<p>Viamed VG900 SPO2 Sensors Test Unit, in very good physical and operational condition, tester&#8217;s actual photo displayed. Hand held tester to test most SPO2 sensors brands, very simple to use</p>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/viamed-vg900-spo2-sensors-test-unit/">Viamed VG900 SPO2 Sensors Test Unit</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="color: #000000;"><strong><span style="color: #0000ff;">Viamed VG900 SPO2 Sensors Test Unit,</span> in very good physical and operational condition, tester&#8217;s actual photo displayed.</strong></span></p>
<ul>
<li><span style="color: #000000;"><strong>Hand held tester to test most SPO2 sensors brands, very simple to use and run on 4 AA batteries.</strong></span></li>
<li><span style="color: #000000;"><strong>Model: VG900</strong></span></li>
<li><span style="color: #000000;"><strong>YOM: 2003</strong></span></li>
<li><span style="color: #000000;"><strong>Direct connect to: Datascope, Nellcor &amp; Ohmeda type SPO2 sensors and connect to MASIMO, Datex-Ohmeda, Spacelabs &amp; Critikon sensors with adapter cables.</strong></span></li>
<li><span style="color: #000000;"><strong>Supplied with:</strong></span>
<ul>
<li><span style="color: #000000;"> <strong>Carrying Case, P/N: 0013110</strong></span></li>
<li><span style="color: #000000;"><strong> 4 adapter cables for:</strong></span>
<ul>
<li><span style="color: #000000;"><strong>MASMO </strong></span></li>
<li><span style="color: #000000;"><strong>Spacelabs, P/N: 0013145</strong></span></li>
<li><span style="color: #000000;"><strong>Critikon, P/N: 0013150</strong></span></li>
<li><span style="color: #000000;"><strong>Datex, P/N; 0013131</strong></span></li>
</ul>
</li>
</ul>
</li>
</ul>
<p>The post <a rel="nofollow" href="https://robinmedical.co.uk/product/viamed-vg900-spo2-sensors-test-unit/">Viamed VG900 SPO2 Sensors Test Unit</a> appeared first on <a rel="nofollow" href="https://robinmedical.co.uk">Robin Medical Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
